Abstract:
The measurement of the volume of blood cells is important for clinical diagnosis and patient management. While digital holography microscopy has been used to obtain such ...Show MoreMetadata
Abstract:
The measurement of the volume of blood cells is important for clinical diagnosis and patient management. While digital holography microscopy has been used to obtain such information, previous off-axis setups usually involve a separated reference beam and are thus not very easy to implement. Here, we use the simple in-line Gabor setup without separation of a reference beam to measure the shape and volume of cells mounted on glass slides. Inherent to the in-line holograms, the reconstructed phase of the object is affected by the virtual image noise, producing errors in the cell volume measurement. We optimized our approach to use a single hologram without phase retrieval, increasing distance between cell and hologram plane to reduce the measurement error of cell volume to less than 6% in some instances. Therefore, the in-line Gabor setup can be a useful and simple tool to obtain volumetric and morphologic cellular information.
Published in: Microscopy ( Volume: 70, Issue: 4, August 2021)
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- Index Terms
- Cell Volume ,
- Volume Measurements ,
- Cell Volume Measurements ,
- Blood Cells ,
- Glass Slides ,
- Image Noise ,
- Simple Setup ,
- Phase Retrieval ,
- Reference Beam ,
- Red Blood Cells ,
- Refractive Index ,
- Background Noise ,
- Electromagnetic Field ,
- Phase Shift ,
- Wavelength Of Light ,
- Focal Plane ,
- Hematology Analyzer ,
- Phase Distribution ,
- Phase Values ,
- Reference Wave ,
- Object Plane ,
- Focusing Parameter ,
- Phase Unwrapping ,
- Mean Corpuscular Volume ,
- Optical Setup ,
- Phase Reconstruction ,
- Effective Imaging ,
- Optical Components
- Author Keywords
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- Index Terms
- Cell Volume ,
- Volume Measurements ,
- Cell Volume Measurements ,
- Blood Cells ,
- Glass Slides ,
- Image Noise ,
- Simple Setup ,
- Phase Retrieval ,
- Reference Beam ,
- Red Blood Cells ,
- Refractive Index ,
- Background Noise ,
- Electromagnetic Field ,
- Phase Shift ,
- Wavelength Of Light ,
- Focal Plane ,
- Hematology Analyzer ,
- Phase Distribution ,
- Phase Values ,
- Reference Wave ,
- Object Plane ,
- Focusing Parameter ,
- Phase Unwrapping ,
- Mean Corpuscular Volume ,
- Optical Setup ,
- Phase Reconstruction ,
- Effective Imaging ,
- Optical Components
- Author Keywords