Abstract:
Antibiotic detection includes direct detection and indirect detection. Indirect detection of antibiotic concentration reflected by the change of bacterial concentration i...Show MoreMetadata
Abstract:
Antibiotic detection includes direct detection and indirect detection. Indirect detection of antibiotic concentration reflected by the change of bacterial concentration is a more intuitive evaluation of antibiotic effect. It can not only accurately evaluate antibiotics, but also be used for tracking evaluation and analysis of antibacterial effects under long-term low-threshold levels. In this paper, a novel method of electrode modification based on AuNPs modified nitrocellulose membrane (NC membrane) was applied to detect bacterial proliferation through electrochemical impedance to accurately quantify antibiotics. The NC-AuNPs-Anti composite membrane was adopted for time-lapse effect of low concentration of amikacin sulfate on E. coli, and the change in AC impedance was analyzed by the equivalent model. t-SNE method was applied to visualize high-dimensional parameters and perform feature screening, and a machine learning model was adopted to accurately predict antibiotics. The experimental results show that this method can reach the antibiotic prediction accuracy of ±2.9E- 03 ~\mu \text{L} /mL at 2, 3, and 4 hours after dosing, so as to provide a better quantitative analysis method for accurate antibiotic evaluation through the electrochemical impedance detection by bacteria proliferation.
Published in: IEEE Sensors Journal ( Volume: 22, Issue: 6, 15 March 2022)