Abstract:
This article presents the integration of a 32-channel neuromodulation system on chip (SoC) that is developed for chronic implantation in humans. The application-specific ...Show MoreMetadata
Abstract:
This article presents the integration of a 32-channel neuromodulation system on chip (SoC) that is developed for chronic implantation in humans. The application-specific integrated circuit (ASIC) offers low-noise recording, a state-of-the-art (SotA) neurostimulator capable of both current- and voltage-controlled stimulation with high-voltage compliance, on-chip 16-bit data digitization as well as safety features such as electrode impedance estimation and charge balancing. The chip communicates through two distinct SPI interfaces for independent command and data transfer. Thus, the developed system constitutes a fully digital, bidirectional 32-channel interface to the brain.
Published in: IEEE Journal of Solid-State Circuits ( Volume: 56, Issue: 8, August 2021)
Funding Agency:
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Neuromodulation ,
- System-on-chip ,
- Neuromodulatory Systems ,
- Data Transfer ,
- Electrode Impedance ,
- Charge Balance ,
- Human Implantation ,
- Chronic Implantation ,
- Local Setting ,
- Current Stimulation ,
- Current Pulse ,
- Noise Floor ,
- Gain Settings ,
- Cathodic Current ,
- Local Stimulation ,
- Large Electrode ,
- Technology Node ,
- Constant Stimulation ,
- Constant Current Stimulator ,
- Input-referred Noise ,
- External Unit ,
- Digital Interface ,
- Small Impedance ,
- Single Command ,
- Stimulation Settings ,
- Flicker Noise ,
- Stimulation Channels ,
- Voltage Divider
- Author Keywords
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Neuromodulation ,
- System-on-chip ,
- Neuromodulatory Systems ,
- Data Transfer ,
- Electrode Impedance ,
- Charge Balance ,
- Human Implantation ,
- Chronic Implantation ,
- Local Setting ,
- Current Stimulation ,
- Current Pulse ,
- Noise Floor ,
- Gain Settings ,
- Cathodic Current ,
- Local Stimulation ,
- Large Electrode ,
- Technology Node ,
- Constant Stimulation ,
- Constant Current Stimulator ,
- Input-referred Noise ,
- External Unit ,
- Digital Interface ,
- Small Impedance ,
- Single Command ,
- Stimulation Settings ,
- Flicker Noise ,
- Stimulation Channels ,
- Voltage Divider
- Author Keywords