Abstract:
Many commercial benchtop impedance analyzers are incapable of acquiring accurate tetrapolar measurements, when large electrode contact impedances are present, as in bioim...Show MoreMetadata
Abstract:
Many commercial benchtop impedance analyzers are incapable of acquiring accurate tetrapolar measurements, when large electrode contact impedances are present, as in bioimpedance measurements using electrodes with micrometer-sized features. External front-end amplifiers can help overcome this issue and provide high common-mode rejection ratio (CMRR) and input impedance. Several discrete component-based topologies are proposed in the literature. In this article, these are compared with new alternatives with regard to their performance in measuring known loads in the presence of electrode contact impedance models, to emulate tetrapolar bioimpedance measurements. These models are derived from bipolar impedance measurements taken from the electrodes of a tetrapolar bioimpedance sensor. Comparison with other electrode models used in the literature established that this is a good and challenging model for bioimpedance front-end amplifier evaluation. Among the examined amplifiers, one of the best performances is achieved with one of the proposed topologies based on a custom front-end with no external resistors (AD8066/AD8130). Under the specific testing conditions, it achieved an uncalibrated worst-case absolute measurement deviation of 4.4% magnitude and 4° at 20 Hz, and 2.2% and 7° at 1 MHz accordingly with loads between 10 Ω and 10 kg. Finally, the practical use of the front-end with the impedance analyzer is demonstrated in the characterization of the bioimpedance sensor, in saline solutions of varying conductivities (2.5-20 mS/cm) to obtain its cell constant. This article serves as a guide for evaluating and choosing front-end amplifiers for tetrapolar bioimpedance measurements both with and without impedance analyzers for practical/clinical applications and material/sensor characterization.
Published in: IEEE Transactions on Instrumentation and Measurement ( Volume: 70)
Funding Agency:
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Bioimpedance Measurements ,
- Front-end Amplifier ,
- Tetrapolar Bioimpedance ,
- Saline Solution ,
- High Resistance ,
- Present Model ,
- High Input ,
- Contact Resistance ,
- Impedance Analysis ,
- Impedance Measurements ,
- Large Resistance ,
- Presence Of Load ,
- Large Electrode ,
- Impedance Model ,
- High Input Impedance ,
- Common-mode Rejection Ratio ,
- Parasite ,
- Instrumentation ,
- Equivalent Circuit ,
- Current Flow ,
- Electrode Impedance ,
- Real Components ,
- Constant Phase Element ,
- Printed Circuit Board ,
- Interface Impedance ,
- Impedance Magnitude ,
- Analog Devices ,
- Magnitude Of Error ,
- Amplifier Output ,
- Phase Delay
- Author Keywords
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Bioimpedance Measurements ,
- Front-end Amplifier ,
- Tetrapolar Bioimpedance ,
- Saline Solution ,
- High Resistance ,
- Present Model ,
- High Input ,
- Contact Resistance ,
- Impedance Analysis ,
- Impedance Measurements ,
- Large Resistance ,
- Presence Of Load ,
- Large Electrode ,
- Impedance Model ,
- High Input Impedance ,
- Common-mode Rejection Ratio ,
- Parasite ,
- Instrumentation ,
- Equivalent Circuit ,
- Current Flow ,
- Electrode Impedance ,
- Real Components ,
- Constant Phase Element ,
- Printed Circuit Board ,
- Interface Impedance ,
- Impedance Magnitude ,
- Analog Devices ,
- Magnitude Of Error ,
- Amplifier Output ,
- Phase Delay
- Author Keywords