Abstract:
This paper presents the optimal operation strategy for home energy management system (HEMS) in the presence of the inverter-based heating, ventilation and air conditionin...Show MoreMetadata
Abstract:
This paper presents the optimal operation strategy for home energy management system (HEMS) in the presence of the inverter-based heating, ventilation and air conditioning (HVAC) system. The main target of this paper is to find the optimal scheduling of the home appliances in line with the optimal operation of the air conditioner system to reduce the daily bills while the end-users discomfort index would be minimized. In this paper, the mathematical formulation is represented in mixed-integer linear programming (MILP) framework to reduce the computational burden and easily be adapted by hardware for implementation. The HEMS is the main responsible for optimal scheduling of controllable and interruptible loads as well as serving the fixed loads. The electricity tariff is based on time-of-use (TOU) mechanism and three different tariffs have been considered during the daily consumptions. The simulation results for the daily operation of a residential home confirms that the proposed model can effectively reduce the electricity bill while the consumer predefined comfort level is appropriately maintained.
Date of Conference: 09-12 June 2020
Date Added to IEEE Xplore: 06 August 2020
ISBN Information: