Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (...Show MoreMetadata
Abstract:
Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (RBD) of the TrueBeam (Varian Medical Systems, Palo Alto, CA, USA), has been used for modeling of the Eclipse (Varian Medical Systems) treatment planning system. However, RBD does not provide multi-leaf collimator (MLC) parameters, such as MLC leaf transmission factor (LTF) and dosimetric leaf gap (DLG). We performed a web-based multi-institutional survey to investigate these parameters as well as the measurement protocols and customization of the parameters for intensity-modulated radiotherapy (IMRT) and/or volumetric modulated radiotherapy (VMAT) commissioning. We collected 69 sets of linear accelerator (linac) data from 58 institutions. In order to measure MLC parameters, most institutions used farmer-type ionization chambers with a sensitive volume of 0.6 cm3, water phantoms, source surface distance of 90 cm with 10 cm depth, and a vendor-provided plan. The LTF showed small inter-unit variabilities, although the DLG showed large variations. For optimization of the parameters for IMRT/VMAT calculations, DLG values were upwardly adjusted at many institutions, whereas the LTF values were modestly changed. We clarified that MLC parameters were measured under the same conditions at more than half of the facilities. Most institutions customized parameters in a similar manner for IMRT/VMAT. The median measured and customized values obtained in our study will be valuable to verify MLC installation accuracy and to shorten the iterative processes of finding the optimal values.
Published in: Journal of Radiation Research ( Volume: 61, Issue: 1, December 2019)
Page(s): 307 - 313
ISSN Information:
DOI: 10.1093/jrr/rrz082
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- Index Terms
- Treatment Plan ,
- Intensity-modulated Radiotherapy ,
- Multileaf Collimator ,
- Intensity-modulated Radiotherapy Treatment Plans ,
- Volumetric Modulated Radiotherapy ,
- Multi-institutional Survey ,
- Measurement Protocol ,
- Varian Medical Systems ,
- Treatment Planning System ,
- Water Phantom ,
- Half Of Facilities ,
- Measurement Device ,
- Field Size ,
- Dose Calculation ,
- Photon Beam ,
- Institutional Values ,
- Fine-tuning Of Parameters ,
- 3D Detection ,
- Amount Of Adjustment
- Author Keywords
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- Index Terms
- Treatment Plan ,
- Intensity-modulated Radiotherapy ,
- Multileaf Collimator ,
- Intensity-modulated Radiotherapy Treatment Plans ,
- Volumetric Modulated Radiotherapy ,
- Multi-institutional Survey ,
- Measurement Protocol ,
- Varian Medical Systems ,
- Treatment Planning System ,
- Water Phantom ,
- Half Of Facilities ,
- Measurement Device ,
- Field Size ,
- Dose Calculation ,
- Photon Beam ,
- Institutional Values ,
- Fine-tuning Of Parameters ,
- 3D Detection ,
- Amount Of Adjustment
- Author Keywords