Loading [MathJax]/extensions/MathMenu.js
High Data-Rate Neutron-Sensitive Pixelated Detector Using Silicon Photomultiplier | IEEE Conference Publication | IEEE Xplore

High Data-Rate Neutron-Sensitive Pixelated Detector Using Silicon Photomultiplier


Abstract:

We report on the design and performance of a neutron-sensitive pixelated detector using an array of silicon photomultiplier (SiPM) sensors. The proof-of-concept design co...Show More

Abstract:

We report on the design and performance of a neutron-sensitive pixelated detector using an array of silicon photomultiplier (SiPM) sensors. The proof-of-concept design consists of an 8 × 8 array of SiPM sensors coupled with an 8 × 8 array of 6Li-enriched glass scintillator (GS20) cubes. Each scintillator cube, of size 2 mm × 2 mm × 2 mm, is placed directly over each element in the sensor array. Each sensor is read out and processed using a simple comparator for pulse height discrimination. Individual counts are then recorded using a Xilinx ZYNQ-based system on chip. Tests performed at the Double-Axis Diffractometer (2X-C) and the High-Resolution Neutron Powder Diffractometer (PSD) beamlines at Missouri University Research Reactor (MURR) show a linear response of individual sensor element up to 100 kHz over an area of 0.2 cm × 0.2 cm, which is equivalent to 2.5 MHz/cm2. The detector efficiency at a neutron wavelength of 4.1 A was measured to be 74.6% relative to the̊ detection efficiency of a 1-inch diameter 10-atm 3He gas detector. The pixel crosstalk was estimated to be less than 3%. The gamma sensitivity was measured to be 1 × 10-3 using calibrated 60Co gamma source at the optimal discriminator setting of the detector.
Date of Conference: 26 October 2019 - 02 November 2019
Date Added to IEEE Xplore: 09 April 2020
ISBN Information:

ISSN Information:

Conference Location: Manchester, UK
References is not available for this document.

Select All
1.
Kanaki, K., et al “Detector Rates for the Small Angle Neutron Scattering Instruments at the European Spallation Source.” Journal of Instrumentation, vol. 13, no. 07, 2018, doi: 10.1088/1748-0221/13/07/p07016.
2.
Piscitelli, F., et al “Characterization of the Multi-Blade 10B-Based Detector at the CRISP Reflectometer at ISIS for Neutron Reflectometry at ESS.” Journal of Instrumentation, vol. 13, no. 05, Aug. 2018, doi: 10.1088/17480221/13/05/p05009.
3.
Klein, Martin, and Christian J. Schmidt. “CASCADE, Neutron Detectors for Highest Count Rates in Combination with ASIC/FPGA Based Readout Electronics.” Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 628, no. 1, 2011, pp. 9–18., doi: 10.1016/j.nima.2010.06.278.
4.
Scintacor, “Glass Scintillator: Lithium Glass Scintillator for Neutron Detection ”. datasheet. Scintacor. 2014 [Revised Aug 2017].
5.
Wang, C. L., and Riedel, R. A. “Improved Neutron-Gamma Discrimination for a 6 Li-Glass Neutron Detector Using Digital Signal Analysis Methods.” Review of Scientific Instruments, vol. 87, no. 1, 2016, p. 013301., doi: 10.1063/1.4939821.
6.
Sens L, “C-Series Low Noise, Blue-Sensitive Silicon Photomultipliers ”, datasheet. 2014