Abstract:

The mechanical design for both the insulating vacuum system and the cavity vacuum system of the APT ED&D Cryomodule is summarized. The pre-cooldown pressure limits for th...Show More

Abstract:

The mechanical design for both the insulating vacuum system and the cavity vacuum system of the APT ED&D Cryomodule is summarized. The pre-cooldown pressure limits for the insulating vacuum and the cavity vacuum are 10/sup -5/ Torr and 10/sup -6/ Torr, respectively. In addition, the cold cavity operating pressure limits are 10 Torr for the insulating system and 10 Torr for the cavity system. The designs of these systems utilize both turbomolecular pumps and the cold surfaces of the superconducting Nb cavities to arrive at and maintain their operating vacuum pressures. A synopsis of the analysis undertaken to predict the vacuum system performance is also presented.
Date of Conference: 27 March 1999 - 02 April 1999
Date Added to IEEE Xplore: 06 August 2002
Print ISBN:0-7803-5573-3
Conference Location: New York, NY, USA

Contact IEEE to Subscribe

References