The purpose of this standard is to specify technical performance requirements and performance testing requirements for those purchasing and using non-alarming Personal Em...Show MoreScope:The scope of this standard is to establish minimum performance criteria and test requirements for nonalarming radiation detectors used to manage the exposure of emergency...Show More
Purpose:The purpose of this standard is to specify technical performance requirements and performance testing requirements for those purchasing and using non-alarming personal em...Show More
Metadata
Abstract:
The purpose of this standard is to specify technical performance requirements and performance testing requirements for those purchasing and using non-alarming Personal Emergency Radiation Detectors PERDs for Homeland Security and other radiological emergency applications.
Scope:
The scope of this standard is to establish minimum performance criteria and test requirements for nonalarming radiation detectors used to manage the exposure of emergency responders to photon radiation. The detectors shall provide rapid and clear indication of the level of radiation exposure. Emergency responders include fire services, law enforcement, and medical services. Other possible users include critical infrastructure key resources (CIKR) such as heavy equipment, transportation, and utilities personnel and members of the public who may be involved in emergency situations.
Purpose:
The purpose of this standard is to specify technical performance requirements and performance testing requirements for those purchasing and using non-alarming personal emergency radiation detectors (PERDs) for Homeland Security and other radiological emergency applications. The users of non-alarming PERDs are responders performing time-sensitive, critical missions such as saving lives, property, and/or otherwise mitigating the effects of radiological emergencies. PERDs can be of two types, either alarming electronic or non-alarming. Both types of PERDs have radiation response ranges appropriate for radiation emergencies. Alarming PERDS are addressed in ANSI ...
Date of Publication: 18 July 2014
Electronic ISBN:978-0-7381-9120-1
ICS Code: 17.240 - Radiation measurements
Persistent Link: https://ieeexplore.ieee.org/servlet/opac?punumber=6860216
References is not available for this document.
Select All
1.
ANSI N13.11-2009 Criteria for Testing Personnel Dosimetry Performance.
2.
ANSI N42.17A-1989, American National Standard for Performance Specifications for Health Physics Instrumentation-Portable Instrumentation for Use in Normal Environmental Conditions.
3.
ANSI N42.17C-1989, American National Standard Performance Specifications for Health Physics Instrumentation-Portable Instrumentation for Use in Extreme Environmental Conditions.
4.
ANSI N42.20-2003, American National Standard Performance Criteria for Active Personnel Radiation Monitors.
5.
ANSI N42.32-2006, American National Standard Performance Criteria for Alarming Personnel Radiation Detectors for Homeland Security.
6.
ANSI N42.33-2003, American National Standard for Portable Radiation Detection Instrumentation for Homeland Security.
7.
ANSI N42.37-2006, American National Standard for Training Requirements for Homeland Security Purposes Using Radiation Detection Instrumentation for Interdiction and Prevention.
8.
ANSI N42.49A-2011, American National Standard for Performance Criteria for Alarming Electronic Personal Emergency Radiation Detectors (PERDs) for Exposure Control.
9.
ANSI N322-1997 (reaff. 2009), American National Standard Inspection, Test, Construction, and Performance Requirements for Direct Reading Electrostatic/Electroscope Type Dosimeters.
10.
ANSI N323A-1997, American National Standard Radiation Protection Instrumentation: Test and Calibration, Portable Survey Instruments.
11.
Department of Homeland Security (DHS), 2008, Planning Guidance for Protection and Recovery Following Radiological Dispersal Device (RDD) and Improvised Nuclear Device (IND) Incidents; Notice 73FR149.
12.
IAEA-EPR-First Responders, 2006, Manual for First Responders to a Radiological Emergency.
13.
IAEA-TECDOC-1432, 2005, Development of an Extended Framework for Emergency Response Criteria.
14.
ICRP Publication 96, 2005, Protecting People against Radiation Exposure in the Event of a Radiological Attack.
15.
IEC 60846-1, 2005, Performance, Type Test and Calibration requirements for Ambient and/or Directional Dose Equivalent Rate Meters for Beta, X or Gamma Radiation-Part 1 Normal Range to 1 Rem h-1.
16.
IEC 60846-2, 2005, Performance, Type Test and Calibration requirements for Ambient and/or Directional Dose Equivalent Rate Meters for Beta, X or Gamma Radiation-Part 2 High Range to 1,000 Rem h-1.
17.
IEC 61526, 2002, Performance, Test and Calibration Requirements for Personnel Alarming Electronic Dosimeters with a Range to 10 Rem and Energy Response from 60 keV to 3 MeV.
18.
ISO/IEC 10373-1 Identification cards-Test Methods-Part 1: General Characteristics Tests.
19.
ISO 4037-1, X and Gamma Reference Radiation for Calibrating Dosemeters and Doserate Meters and for Determining Their Response as a Function of Photon Energy-Part 1: Radiation Characteristics and Production Methods.
20.
ISO 4037-2, X and Gamma Reference Radiation for Calibrating Dosemeters and Doserate Meters and for Determining Their Response as a Function of Photon Energy-Part 2: Dosimetry for Radiation Protection over the Energy Ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV.
21.
NCRP Commentary No. 19, 2005, Key Elements of Preparing Emergency Responders for Nuclear and Radiological Terrorism.
22.
NCRP Report No. 138, 2001, Management of Terrorist Events Involving Radioactive Material.
23.
NFPA 1971, 2007, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.
24.
NFPA 1982, 2007, National Fire Protection Association Standard on Personal Alert Safety Systems (PASS), 2007 Edition.
25.
NFPA 472, 2008, Standard for Competence of Responders to Hazardous Materials/Weapons of Mass Destruction Incidents.
26.
UL 94, 1996, Standard for Tests for Flammability of Plastic Materials for Parts in Devices and Appliances.
27.
UL 913, Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III, Division 1, Hazardous (Classified) Locations.