Isolated converter topologies for power factor correction — A comparison | IEEE Conference Publication | IEEE Xplore

Isolated converter topologies for power factor correction — A comparison


Abstract:

This paper deals with the analysis, design and analog based hardware implementation of three different topologies of high frequency isolated AC-DC converters in discontin...Show More

Abstract:

This paper deals with the analysis, design and analog based hardware implementation of three different topologies of high frequency isolated AC-DC converters in discontinuous current mode (DCM) of operation for power factor correction and output voltage regulation. These switching converters are designed for low power rating and low output voltage, typically 20.25 W with 13.5 V in DCM operation. Modelling and simulation is carried out in a standard PSIM software environment. Laboratory prototypes of the proposed converters in DCM operation are developed and test results are presented to compare with the simulation results.
Date of Conference: 28-30 December 2011
Date Added to IEEE Xplore: 09 February 2012
ISBN Information:
Conference Location: Bhubaneswar, India

Contact IEEE to Subscribe

References

References is not available for this document.