Harmonic compensation using eleven level shunt active filter | IEEE Conference Publication | IEEE Xplore

Harmonic compensation using eleven level shunt active filter


Abstract:

A new shunt active filter is proposed here to reduce the harmonic contents in source voltage and source currents of a harmonic polluted three phase system supplying a non...Show More

Abstract:

A new shunt active filter is proposed here to reduce the harmonic contents in source voltage and source currents of a harmonic polluted three phase system supplying a non-linear load. The shunt active filter is designed with a eleven level cascaded H-bridge inverter. To generate the required compensation currents multi carrier PWM Currents are extracted from the load power using Synchronous Detection Method. Simulation of the active filter with proposed current control and dc bus control is presented. The harmonic filter reduces the harmonic contents in source currents as well as the source voltage multilevel shunt active filter does not require an interfacing transformer to connect it with the high power system. It reduces the filter current ripples and improve source power factor.
Date of Conference: 29-31 July 2010
Date Added to IEEE Xplore: 30 September 2010
ISBN Information:
Conference Location: Karur, India

Contact IEEE to Subscribe

References

References is not available for this document.