Abstract:
A method has been proposed to model the illumination characteristics of a typical wire bonder vision system. The proposed model can be used to calibrate the illumination ...Show MoreMetadata
Abstract:
A method has been proposed to model the illumination characteristics of a typical wire bonder vision system. The proposed model can be used to calibrate the illumination of the vision system to ensure the same level of illumination brightness across different machines, given the same lighting level setting. The approach to extract the machine illumination model is semi-empirical and the model provides a closed-form solution
Date of Conference: 26-29 August 2006
Date Added to IEEE Xplore: 15 May 2007
ISBN Information: