Abstract:

We classify standby redundancy design space in process-control programs into the following three categories: cold standby, warm standby, and hot standby. Design parameter...Show More

First Page of the Article

Abstract:

We classify standby redundancy design space in process-control programs into the following three categories: cold standby, warm standby, and hot standby. Design parameters of warm standby are identified and the reliability of a system using warm standby is evaluated and compared with that of hot standby. Our analysis indicates that the warm standby scheme is particularly suitable for long-lived unmaintainable systems, especially those operating in harsh environments where burst hardware failures are possible. The feasibility of warm standby is demonstrated with a simulated chemical batch reactor system.<>
Published in: IEEE Transactions on Software Engineering ( Volume: 20, Issue: 8, August 1994)
Page(s): 658 - 663