Root-Causes of Bias Instability Noise in Mode-Split MEMS Gyroscopes | IEEE Journals & Magazine | IEEE Xplore

Root-Causes of Bias Instability Noise in Mode-Split MEMS Gyroscopes


Abstract:

This paper presents a general instability model of mode-split MEMS gyroscopes. The proposed model can accurately predict the bias instability of a given device based on t...Show More

Abstract:

This paper presents a general instability model of mode-split MEMS gyroscopes. The proposed model can accurately predict the bias instability of a given device based on the applied angular rate and system parameters. The model consists of two noise models: bias instability and scale factor instability. Four flicker noise sources are considered that are the most significant contributors. These include phase flicker noise of the drive capacitance to voltage converter, sense analog-to-digital (ADC) scale factor instability, proof mass voltage flicker noise, and additive flicker noise. All the noise contributors are thoroughly analyzed and experimentally characterized on four triaxial research devices. Based on the results of the experimental characterization, the proposed scale factor and bias instability models are verified against the measurement data. We find a good match between the presented model and measurements. As anticipated by the proposed model, a reduction of the phase flicker noise of the drive capacitance to voltage converter has led to up to 50% improvement in bias instability.[2024-0018]
Published in: Journal of Microelectromechanical Systems ( Volume: 33, Issue: 5, October 2024)
Page(s): 514 - 523
Date of Publication: 26 June 2024

ISSN Information:

Funding Agency:


Contact IEEE to Subscribe

References

References is not available for this document.