Ultrasound Imaging-Based Closed-Loop Control of Functional Electrical Stimulation for Drop Foot Correction | IEEE Journals & Magazine | IEEE Xplore

Ultrasound Imaging-Based Closed-Loop Control of Functional Electrical Stimulation for Drop Foot Correction


Abstract:

Open- or closed-loop functional electrical stimulation (FES) has been widely investigated to treat drop foot syndrome, which is typically caused by weakness or paralysis ...Show More

Abstract:

Open- or closed-loop functional electrical stimulation (FES) has been widely investigated to treat drop foot syndrome, which is typically caused by weakness or paralysis of ankle dorsiflexors. However, conventional closed-loop FES control mainly uses kinematic feedback, which does not directly capture time-varying changes in muscle activation. In this study, we explored the use of ultrasound (US) echogenicity as an indicator of FES-evoked muscle activation and hypothesized that including US-derived muscle activation, in addition to kinematic feedback, would improve the closed-loop FES control performance compared to the closed-loop control that relies only on the kinematic feedback. A sampled-data observer (SDO) was derived to continuously estimate FES-evoked muscle activations from low-sampled US echogenicity signals. In addition, a dynamic surface controller (DSC) and a delay compensation (DC) term were incorporated with the SDO, denoted as the US-based DSC-DC, to drive the actual ankle dorsiflexion trajectory to the desired profile. The trajectory tracking error convergence of the closed-loop system was proven to be uniformly ultimately bounded based on the Lyapunov–Krasovskii stability analysis. The US-based DSC-DC controller was validated on five participants with no disabilities to control their ankle dorsiflexion during walking on a treadmill. The US-based DSC-DC controller significantly reduced the root-mean-square error of the ankle joint trajectory tracking by 46.52% ± 7.99% ( p < 0.001 ) compared to the traditional DSC-DC controller with only kinematic feedback but no US measurements. The results also verified the disturbance rejection performance of the US-based DSC-DC controller when a plantarflexion disturbance was added. Our control design, for the first time, provides a methodology to integrate US in an FES control framework, which will likely benefit persons with drop foot and those with other mobility disorders.
Published in: IEEE Transactions on Control Systems Technology ( Volume: 31, Issue: 3, May 2023)
Page(s): 989 - 1005
Date of Publication: 30 September 2022

ISSN Information:

Funding Agency:


References

References is not available for this document.