A 65nm Resonant Electro-Quasistatic 5-240uW Human Whole-Body Powering and 2.19uW Communication SoC with Automatic Maximum Resonant Power Tracking | IEEE Conference Publication | IEEE Xplore

A 65nm Resonant Electro-Quasistatic 5-240uW Human Whole-Body Powering and 2.19uW Communication SoC with Automatic Maximum Resonant Power Tracking


Abstract:

Applications like Connected Healthcare through physiological signal monitoring and Secure Authentication using wearable keys can benefit greatly from battery-less operati...Show More

Abstract:

Applications like Connected Healthcare through physiological signal monitoring and Secure Authentication using wearable keys can benefit greatly from battery-less operation. Low power communication along with energy harvesting is critical to sustain such perpetual battery-less operation. Previous studies have used techniques such as Tribo-Electric, Piezo-Electric, RF energy harvesting for Body Area Network devices, but they are restricted to on-body node placements. Human body channel is known to be a promising alternative to wireless radio wave communication for low power operation [1-4], through Human Body Communication, as well as very recently as a medium for power transfer through body coupled power transfer [5]. However, channel length (L) dependency of the received power makes it inefficient for L>40cm. There have also been a few studies for low power communication through the human body, but none of them could provide sustainable battery-less operation. In this paper, we utilize Resonant Electro Quasi-Static Human Body Communication (Res-EQS HBC) with Maximum Resonance Power Tracking (MRPT) to enable channel length independent whole-body communication and powering (Fig.1). We design the first system to simultaneously transfer Power and Data between a HUB device and a wearable through the human body to enable battery-less operation. Measurement results show 240uW, 28uW and 5uW power transfer through the body in a MachineMachine (large devices with strong ground connection) Tabletop (small devices kept on a table, as in [5]) and Wearable-Wearable (small form factor battery operated devices) scenario respectively, independent of body channel length, while enabling communication with a power consumption of only 2.19uW. This enables >25x more power transfer with >100x more efficiency compared to [5] for Tabletop and 100cm Body distance by utilizing the benefits of EQS. The MRPT loop automatically tracks device and posture dependent resonance point changes to maxi...
Date of Conference: 25-30 April 2021
Date Added to IEEE Xplore: 17 May 2021
ISBN Information:

ISSN Information:

Conference Location: Austin, TX, USA
References is not available for this document.

References is not available for this document.

Contact IEEE to Subscribe

References

References is not available for this document.