Wearable Ultrasound Imaging Device for Dynamic Dual-Direction Shear Wave Elastography of Shoulder Muscle | IEEE Journals & Magazine | IEEE Xplore

Wearable Ultrasound Imaging Device for Dynamic Dual-Direction Shear Wave Elastography of Shoulder Muscle


Abstract:

The shoulder is the most mobile joint in the human body, thus requiring intricate coordination of adjacent muscles. Patients suffered from rotator cuff muscle injuries ha...Show More

Abstract:

The shoulder is the most mobile joint in the human body, thus requiring intricate coordination of adjacent muscles. Patients suffered from rotator cuff muscle injuries have several typical symptoms including shoulder pain and difficulty raising the arm, thus reducing work efficiency and compromising the quality of life. Ultrasound has been used widely for shoulder soft tissue imaging as well as ultrasound elastography was introduced in shoulder examination for the dilemma of treating degenerative rotator cuff tears. However, most of the ultrasound examination was performed under a static condition. Providing dynamic information from shoulder muscle is important in clinical applications because the pains sometimes come from various positions of the shoulder during moving. In this study, a customized wearable T-shaped ultrasound transducer (128 + 128 elements) was proposed for shoulder dual-direction shear wave elastography (DDSWE), which provides the SWE for both longitudinal (SW along the muscle fiber) and transverse (SW cross the muscle fiber) directions dynamically. An optical tracking system was synchronized with an ultrasound imaging system to capture shoulder movements in 3-D space with their corresponding ultrasound images. The performance of DDSWE and the accuracy of optical tracking were verified by phantom experiments. Human studies were carried out by volunteers as they are moving their arms. The experimental results show that the bias and precision for the proposed DDSWE in elastic phantom were about 6% and 1.2% for both directions, respectively. A high accuracy of optical tracking was observed using a 3-D motor stage experimental setup. Human experiments show that the shear wave velocities (SWVs) were increased with the angles of shoulder abduction, and the average transverse and longitudinal SWVs were increased from 2.24 to 3.35 m/s and 2.95 to 5.95 m/s with abduction angle from 0° to 60°, respectively, which they are anisotropic-dependent. All the expe...
Page(s): 763 - 774
Date of Publication: 01 January 2024

ISSN Information:

PubMed ID: 38163298

Funding Agency:


References

References is not available for this document.