Abstract:
Wireless sensor nodes capable of acquiring and transmitting biosignals are increasingly important to address future needs in healthcare monitoring. One of the main issues...Show MoreMetadata
Abstract:
Wireless sensor nodes capable of acquiring and transmitting biosignals are increasingly important to address future needs in healthcare monitoring. One of the main issues in designing these systems is the unavoidable energy constraint due to the limited battery lifetime, which strictly limits the amount of data that may be transmitted. Compressed Sensing (CS) is an emerging technique for introducing low-power, real-time compression of the acquired signals before transmission. The recently developed rakeness approach is capable of further increasing CS performance. In this paper we apply the rakeness-CS technique to enhance compression capabilities for electroencephalographic (EEG) signals, and particularly for Evoked Potentials (EP), which are recordings of the neural activity evoked by the presentation of a stimulus. Simulation results demonstrate that EPs are correctly reconstructed using rakeness-CS with a compression factor of 16. Additionally, some interesting denoising capabilities are identified: the high-frequency noise components are rejected and the 60 Hz power line noise is decreased by more than 20dB with respect to the state-of-the-art filtering when rakeness-CS techniques are applied to the EEG data stream.
Date of Conference: 22-25 May 2016
Date Added to IEEE Xplore: 11 August 2016
ISBN Information:
Electronic ISSN: 2379-447X