2013 IEEE 8th International Conference on Industrial and Information Systems

17-20 Dec. 2013

Filter Results

Displaying Results 1 - 25 of 133
  • [Front cover]

    Publication Year: 2013, Page(s): 1
    Request permission for reuse | PDF file iconPDF (1380 KB)
    Freely Available from IEEE
  • [Front cover]

    Publication Year: 2013, Page(s): i
    Request permission for reuse | PDF file iconPDF (106 KB)
    Freely Available from IEEE
  • [Copyright notice]

    Publication Year: 2013, Page(s): ii
    Request permission for reuse | PDF file iconPDF (63 KB)
    Freely Available from IEEE
  • International advisory committee

    Publication Year: 2013, Page(s):iii - iv
    Request permission for reuse | PDF file iconPDF (98 KB)
    Freely Available from IEEE
  • Conference organizing committee

    Publication Year: 2013, Page(s):v - vi
    Request permission for reuse | PDF file iconPDF (107 KB)
    Freely Available from IEEE
  • Technical Program Committee

    Publication Year: 2013, Page(s):vii - viii
    Request permission for reuse | PDF file iconPDF (96 KB)
    Freely Available from IEEE
  • International review panel

    Publication Year: 2013, Page(s):ix - xi
    Request permission for reuse | PDF file iconPDF (251 KB)
    Freely Available from IEEE
  • Message from the general chair

    Publication Year: 2013, Page(s): xii
    Request permission for reuse | PDF file iconPDF (110 KB) | HTML iconHTML
    Freely Available from IEEE
  • Table of content

    Publication Year: 2013, Page(s):xiii - xxx
    Request permission for reuse | PDF file iconPDF (318 KB)
    Freely Available from IEEE
  • A case study to demonstrate the benefit of using synchrophasor signals for power system stabilizers

    Publication Year: 2013, Page(s):1 - 5
    Cited by:  Papers (2)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (901 KB) | HTML iconHTML

    This paper presents a case where the design of a Power System Stabilizer (PSS) to achieve desired damping using local speed feedback signals is difficult using the conventional design technique. It is shown that synchrophasor based two input power system stabilizer can be designed without much difficulty to achieve the desired damping. Eigenanalysis is performed on the reduced equivalent of New En... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A study of load and line characteristics on power system damping performance

    Publication Year: 2013, Page(s):6 - 11
    Cited by:  Papers (1)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (919 KB) | HTML iconHTML

    Loads supplied by controlled power electronic converters are increasingly emerging into power systems. Generally, it is assumed that these loads are having constant power load characteristics. However, modeling of an EV charging load having power electronic grid interface and a voltage controlled dc link, has identified a load characteristic which combines constant power and negative exponential l... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Optimal design of a grid connected hybrid electrical energy system using evolutionary computation

    Publication Year: 2013, Page(s):12 - 17
    Cited by:  Papers (5)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (817 KB) | HTML iconHTML

    Hybrid Energy Systems (HESs) are becoming attractive solution for both grid connected and stand-alone applications. A number of factors need to be considered in designing HESs where multi-objective optimization becomes useful. Multi-objective optimization is used in this study to arrive at optimum systems designs for a grid connected HES considering Levelized Energy Cost (LEC) and Level of Grid In... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Local control of heat pump water heaters for voltage control with high penetration of residential PV systems

    Publication Year: 2013, Page(s):18 - 23
    Cited by:  Papers (2)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (1399 KB) | HTML iconHTML

    In Japan, large amount of photovoltaic (PV) systems will be installed in the future power system due to rising environmental concern. Large installation of these PV systems causes voltage rise at the end of the distribution line due to reverse power flow. In order to alleviate this problem, load control at the customer end is considered as a major study of this research. In this paper, heat pump w... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Control techniques for torque ripple minimization in switched reluctance motor: An overview

    Publication Year: 2013, Page(s):24 - 29
    Cited by:  Papers (4)
    Request permission for reuse | PDF file iconPDF (475 KB) | HTML iconHTML
    Freely Available from IEEE
  • Model in the loop testing of complex reactive systems

    Publication Year: 2013, Page(s):30 - 35
    Cited by:  Papers (3)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (571 KB) | HTML iconHTML

    Currently there is a new trend in the design of Complex Reactive Systems (CRS) towards model based development. Software components are no longer hard written in C or Assembler code but modeled with MATLAB/Simulink, Statemate or similar tools. Model based designs allow development of high level models that can be used for simulations in very early stages of the design process. However the quality ... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • High resolution stepper motor controller for tunable laser

    Publication Year: 2013, Page(s):36 - 41
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (725 KB) | HTML iconHTML

    Tunable laser system requires high resolution and accuracy in position of the wave selective optical element, which can be attained through the use of stepper motor. This paper focuses on the stepper motor controller, with the feedback to improve the accuracy and the microstepping technique to improve the resolution. Sine cosine and trapezoidal current controlling techniques for the micro stepping... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Comparison of PI & fuzzy logic controller for shunt active power filter

    Publication Year: 2013, Page(s):42 - 47
    Cited by:  Papers (10)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (1019 KB) | HTML iconHTML

    Shunt Active Power Filter (SAPF), when used with non linear loads, provides an elegant solution to reactive power compensation as well as harmonic mitigation leading to improvement in power quality. The present study deals with fuzzy logic control for SAPF. Its superiority over PI type of controller is demonstrated through simulation results. View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Combating interference in power control MAC protocol for wireless ad hoc networks

    Publication Year: 2013, Page(s):48 - 52
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (706 KB) | HTML iconHTML

    The limitation in battery power is now becoming a critical problem for the efficiency and performance of Wireless Ad Hoc Networks. A transmit power control protocol is proposed which considers limited power to transmit the packets to receiver node unaffected by the wastage of energy due to collisions and retransmissions of lost packets because of hidden nodes and interfering nodes existing within ... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A low-latency and energy efficient forward handover scheme for LTE-femtocell networks

    Publication Year: 2013, Page(s):53 - 58
    Cited by:  Papers (2)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (469 KB) | HTML iconHTML

    Femtocells are small, inexpensive, low power cell sites, which are used to improve indoor capacity and coverage. They are generally consumer deployed and are connected to their own wired broadband backhaul connections. A large number of femtocell deployments in long term evolution (LTE) networks are highly anticipated. One of the main technical challenges of LTE-femtocell networks is the handover ... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Reconfigurable hybrid spectrum sensing technique for cognitive radio

    Publication Year: 2013, Page(s):59 - 62
    Cited by:  Papers (3)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (584 KB) | HTML iconHTML

    Due to massive entry of wireless services with inefficient spectrum resource utilization led to an apparent scarcity of usable radio bandwidth. Cognitive radio is well organized to utilize vacancy in the radio spectrum due to absence of primary user. Spectrum sensing i.e., detecting the presence of primary users in a licensed spectrum is the fundamental task in cognitive radio. This leads to emerg... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A dynamic resource management scheme for two-tier LTE femtocell networks

    Publication Year: 2013, Page(s):63 - 68
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (711 KB) | HTML iconHTML

    Recently, the femtocell concept has received considerable attention both in academic and industry as a promising solution for the deep indoor coverage problem as well as the increasing data demand of mobile devices. Large scale femtocell deployments are hindered mainly by the cross tier interference problem spawned by their inherent uncoordinated deployment and the shared use of the limited spectr... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • An effective RC4 stream cipher

    Publication Year: 2013, Page(s):69 - 74
    Cited by:  Papers (8)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (1064 KB) | HTML iconHTML

    RC4 is the most widely used stream cipher around. A lot of modifications of RC4 cipher can be seen in open literature. Most of them enhance the secrecy of the cipher and the security levels have been analyzed theoretically by using mathematics. In this paper, a new effective RC4 cipher is proposed and the security analysis has been done using Shannon's Secrecy theories where numerical values are o... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Software implementation level countermeasures against the cache timing attack on advanced encryption standard

    Publication Year: 2013, Page(s):75 - 80
    Cited by:  Papers (1)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (1207 KB) | HTML iconHTML

    Advanced Encryption Standard (AES) is a symmetric key encryption algorithm which is extensively used in secure electronic data transmission. When introduced, although it was tested and declared as secure, in 2005, a researcher named Bernstein claimed that it is vulnerable to side channel attacks. The cache-based timing attack is the type of side channel attack demonstrated by Bernstein, which uses... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • PLC security and critical infrastructure protection

    Publication Year: 2013, Page(s):81 - 85
    Cited by:  Papers (7)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (1106 KB) | HTML iconHTML

    Programmable Logic Controllers (PLCs) are the most important components embedded in Industrial Control Systems (ICSs). ICSs have achieved highest standards in terms of efficiency and performance. As a result of that, higher portion of infrastructure in industries has been automated for the comfort of human beings. Therefore, protection of such systems is crucial. It is important to investigate the... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Firewall model for cloud computing

    Publication Year: 2013, Page(s):86 - 91
    Cited by:  Papers (3)
    Request permission for reuse | Click to expandAbstract | PDF file iconPDF (1095 KB) | HTML iconHTML

    Cloud computing is becoming increasingly popular in the business world due to the advantages that it offers by eliminating the need to have infrastructure within business premises and dedicated staff to maintain infrastructure. Apart from the advantages the cloud offers, it can also bring in some potential security threats to the organization by not having organization specific firewalls, monitori... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.