Abstract:
This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdo...Show MoreScope:This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdo...Show More
Purpose:Capabilities required of ac high voltage circuit breakers intended to protect generator circuits, may be very different from the capabilities required for standard high v...Show More
Metadata
Abstract:
This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped storage installations are considered special applica...
Scope:
This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped storage installations are considered special applica...
Purpose:
Capabilities required of ac high voltage circuit breakers intended to protect generator circuits, may be very different from the capabilities required for standard high voltage circuit breakers, intended for service protecting standard distribution circuits which are specified in other industry standards. [Here we refer to C37.04, C37.06 , C37.09, and C37.010 as well as IEC 62271-100.] The purpose of this document is to provide standard requirements, tests and application guidelines for ac high-voltage generator circuit breakers.
Date of Publication: 30 October 2015
Electronic ISBN:978-0-7381-9852-1
ICS Code: 29.120.40 - Switches
Persistent Link: https://ieeexplore.ieee.org/servlet/opac?punumber=7320941