Abstract:

This paper presents the qualification of a transient recorder used in a system for traceable measurements of Very Fast Transients. The system is designed for traceable me...Show More

Abstract:

This paper presents the qualification of a transient recorder used in a system for traceable measurements of Very Fast Transients. The system is designed for traceable measurements of VFT up to 100 kV, having a target settling time , a peak voltage error , and a front time error . The rise time of the digitizer is 1.6 ns at 50Ω and 1.2 ns at 1 MΩ. Step responses show settling times of 4.5 ns. A convolution method gives a peak voltage error of 0.12% and a front time error of 4.1% for 4.5ns front times.