Abstract:
This paper studies a three-phase contactless power transformer with a magnet yoke at a horizontal misalignment. The self-inductances and mutual inductances are simulated ...Show MoreMetadata
Abstract:
This paper studies a three-phase contactless power transformer with a magnet yoke at a horizontal misalignment. The self-inductances and mutual inductances are simulated with three-dimensional finite element method and the characteristics of inductances are formulated as simple equations. Numerical simulation results confirm that the misalignment causes unbalance currents and reduction in transfer efficiency.
Date of Conference: 13-16 November 2016
Date Added to IEEE Xplore: 02 February 2017
ISBN Information:
Conference Location: Chiba, Japan