Abstract:

This work proposes the zero sequence voltage component (ZSVC) of the stator three-phase voltages as a method for detecting winding inter-turns short circuits in permanent...Show More

Abstract:

This work proposes the zero sequence voltage component (ZSVC) of the stator three-phase voltages as a method for detecting winding inter-turns short circuits in permanent magnet synchronous motors PMSM operating under transient conditions. Additionally it proves the linear relationship between the ZSVC and speed, which is effectively used as a fault severity index. The acquired ZSVC temporal signal is processed by means of the Hilbert-Huang transform (HHT). Experimental results presented in this work show the advantages of the method to provide helpful data for online diagnosis of stator winding inter-turn faults.
Date of Conference: 30 August 2011 - 01 September 2011
Date Added to IEEE Xplore: 15 September 2011
ISBN Information:
Conference Location: Birmingham, UK

References

References is not available for this document.