Scheduled System Maintenance
On Tuesday, September 26, IEEE Xplore will undergo scheduled maintenance from 1:00-4:00 PM ET.
During this time, there may be intermittent impact on performance. We apologize for any inconvenience.

IRE Transactions on Bio-Medical Electronics

Issue 3 • July 1962

Filter Results

Displaying Results 1 - 17 of 17
  • [Table of contents]

    Publication Year: 1962, Page(s): c1
    Request permission for commercial reuse | PDF file iconPDF (80 KB)
    Freely Available from IEEE
  • IRE Professional Group on Bio-Medical Electronics

    Publication Year: 1962, Page(s): c2
    Request permission for commercial reuse | PDF file iconPDF (355 KB)
    Freely Available from IEEE
  • In defense of gadgeteering

    Publication Year: 1962, Page(s): 175
    Request permission for commercial reuse | PDF file iconPDF (170 KB)
    Freely Available from IEEE
  • Present Status of Fetal Electrocardiography

    Publication Year: 1962, Page(s):176 - 180
    Cited by:  Papers (2)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (1170 KB)

    Fetal electrocardiography, an infant but vigorous young discipline, seems to be rapidly emerging as a useful tool for that biological research and medical practice which concerns the unborn heart. Based upon wide experience, it will be useful to survey the status of fetal electrocardiography, pointing out the possibilities as well as limitations. The significance in terms of capability for early s... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A Simple, Bidirectional, Transistor Switch for Sine-Wave Trains

    Publication Year: 1962, Page(s):181 - 184
    Cited by:  Papers (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2599 KB)

    Trains of sine waves of varying duration and frequency are sometimes required in auditory research or in experiments where nerve or muscle preparations are stimulated. One of the problems involved in such work is the need for a stimulus which is symmetrical to ground (pedestal-free) and which has a small rise time, so that the intensity-latency relationship can be correctly evaluated. It is someti... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • The SETAR and Its Uses for Recording Physiological and Behavioral Data

    Publication Year: 1962, Page(s):185 - 189
    Cited by:  Papers (15)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2917 KB)

    The SETAR (Serial Event Timer and Recorder) is an electronic digital elapsed-time recorder with punched paper tape output. It is a multichannel machine and will time and record the occurrence of successive events within a single channel or between different channels. An event is anything which will make or break one or more of the input circuits. The SETAR can directly record behavioral variables,... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • An Automatic System for Processing Microelectrode Data

    Publication Year: 1962, Page(s):190 - 194
    Cited by:  Papers (3)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (1305 KB)

    A data processing system has been designed and built which converts single unit microelectrode recordings obtained on analog magnetic tape into a punched paper tape record. The conversion process preserves the exact time sequence in which the neurological events occur. The punched paper tape record can be used to obtain hard copy via a "Flexowriter" and to punch IBM cards for computation on any on... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Echo Capsule for Medical Use (A Batteryless Endoradiosonde)

    Publication Year: 1962, Page(s):195 - 199
    Cited by:  Papers (29)  |  Patents (4)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (1939 KB)

    A new type of a swallowable radio transmitter, ECHO CAPSULE, is described along with some clinical experiments. Unlike other similar capsules which have been reported, this capsule contains no battery and is energized from outside the human body. The energy is converted into dc by the transistor of the oscillator circuit itself, stored into a capacitor and then used as an energy source for the tra... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A Phase-Shift Ultrasonic Flowmeter

    Publication Year: 1962, Page(s):199 - 203
    Cited by:  Papers (8)  |  Patents (4)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (1906 KB)

    An ultrasonic flowmeter using phase-shift techniques has been developed to measure phasic blood flow in animals. Lead zirconate titanate transducers are located diagonally opposed over the vessel so that 1-Mc ultrasound may be transmitted alternately upstream and downstream. The upstream and downstream transit times are measured by heterodyning the 1-Mc receiver crystal output to 10 kc, and then f... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Transistor Equipment for Continuous Recording of Oriented Migratory Behavior in Birds

    Publication Year: 1962, Page(s):204 - 208
    Cited by:  Papers (5)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (1143 KB)

    The migratory behavior of birds has been studied for over 30 years, but a more precise measurement of this behavior is needed to aid in the study of orientation and navigation during migration. The equipment developed for this purpose consists of eight small cages arranged along the axis of the major points of the compass and opening into a large center area. Each cage is provided with a transduce... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A Neuron Model Which Performs Analog Functions

    Publication Year: 1962, Page(s): 209
    Cited by:  Papers (1)
    Request permission for commercial reuse | PDF file iconPDF (396 KB)
    Freely Available from IEEE
  • Comments on "Analog Computer Simulation of a Neural Element"

    Publication Year: 1962, Page(s):210 - 211
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (1065 KB)

    First Page of the Article
    View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Notice of Meeting of the Society for Psychophysiological Research

    Publication Year: 1962, Page(s): 212
    Request permission for commercial reuse | PDF file iconPDF (48 KB)
    Freely Available from IEEE
  • PGBME Affiliates

    Publication Year: 1962, Page(s): 212-a
    Request permission for commercial reuse | PDF file iconPDF (191 KB)
    Freely Available from IEEE
  • IRE Transactions on Bio-Medical Electronics Statement of Editorial Policy

    Publication Year: 1962, Page(s): 212-b
    Request permission for commercial reuse | PDF file iconPDF (376 KB)
    Freely Available from IEEE
  • Information for authors

    Publication Year: 1962, Page(s): 212b
    Request permission for commercial reuse | PDF file iconPDF (376 KB)
    Freely Available from IEEE
  • Institutional listings

    Publication Year: 1962, Page(s): 212c
    Request permission for commercial reuse | PDF file iconPDF (47 KB)
    Freely Available from IEEE

Aims & Scope

This Transactions ceased publication in 1962. The current retitled publication is Biomedical Engineering, IEEE Transactions on

Full Aims & Scope