By Topic

IEEE Transactions on Industry and General Applications

Issue 6 • Date Nov. 1970

Filter Results

Displaying Results 1 - 25 of 26
  • IEEE Transactions on Industry and General Applications - Table of contents

    Publication Year: 1970, Page(s): c1
    Request permission for commercial reuse | PDF file iconPDF (443 KB)
    Freely Available from IEEE
  • IEEE Industry and General Applications Group

    Publication Year: 1970, Page(s): c2
    Request permission for commercial reuse | PDF file iconPDF (199 KB)
    Freely Available from IEEE
  • 1970 IGA Group Annual Meeting

    Publication Year: 1970, Page(s):529 - 533
    Request permission for commercial reuse | PDF file iconPDF (6920 KB)
    Freely Available from IEEE
  • Safety System Dynamics for Consumer Products: Some Factors Affecting Decisions About Safety

    Publication Year: 1970, Page(s):534 - 539
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2631 KB)

    First Page of the Article
    View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Electric Motors Versus Gas Engines as Prime Movers in Producing Operations

    Publication Year: 1970, Page(s):540 - 544
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2032 KB)

    Of the major problems in the design of oil production facilities is the selection of prime movers for power-driven equipment required in the production and transportation of crude oil. The economic reasons behind the trend in the more widespread use of electric motors from the historical use of gas engines for the large percentage of installations are summarized. Comparative characteristics of ele... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Important Functions Performed by an Effective Equipment Grounding System

    Publication Year: 1970, Page(s):545 - 552
    Cited by:  Papers (6)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (3045 KB)

    The equipment grounding system concerns itself with the interconnection and grounding of nonelectrical conducting material which either encloses or is adjacent to energized electric power conductors. Its purpose is to assure that the building containing the electrical system, or the occupants of that building, are not subjected to a dangerous or objectionable environment condition incidental to th... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Voltage Control of the Three-Phase Induction Motor by Thyristor Switching: a Time-Domain Analysis Using the α--β--0 Transformation

    Publication Year: 1970, Page(s):553 - 562
    Cited by:  Papers (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (1465 KB)

    Phase-controlled thyristors connected back-to-back can be used to control the speed of induction motors. The motor windings carry a discontinuous pattern of current. The extinction angle of the thyristors is a function of the firing angle and the motor parameters. The α--β--0 transformation has been used to obtain a complete solution of the voltage equations for a constant speed of... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Instrument Transformers

    Publication Year: 1970, Page(s):563 - 569
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (3311 KB)

    Instrument transformers serve an important role in the protective circuits of industrial and commercial electric power systems. They are auxiliary devices that are used in the measurement of current and voltage. They reproduce in their secondary circuits, in a definite and known proportion suitable for use in protective devices, the current or voltage of their primary circuits with the phase relat... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Output Voltage in Three-Phase Pulsewidth-Modulated Inverters

    Publication Year: 1970, Page(s):570 - 579
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2117 KB)

    A theoretical analysis of pulsewidth control in three-phase pulsewidth-modulated inverters, is presented. Two general classifications of commutation schemes are discussed with respect to controllability of output voltage and commutation requirements. It is shown that for one scheme the output waveform is always defined regardless of load conditions but for the other scheme the output waveform is d... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Automated Fueling for the Jet-Age Airport

    Publication Year: 1970, Page(s):580 - 597
    Cited by:  Patents (3)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (8880 KB)

    The underground fueling system at John F. Kennedy International Airport provides for handling as many as 28 segregations of fuel. These fuels are transferred from a main or bulk storage area, laid out to accommodate 90 large tanks to a satellite or day tank area which is 2 miles closer to the terminals and consists of 40 small tanks. Identity of product by supplier and grade must be maintained in ... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Spot Networks and Connected Building Systems

    Publication Year: 1970, Page(s):598 - 606
    Cited by:  Papers (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2869 KB)

    When spot networks are used to supply large commercial building loads, the utility system and the building wiring must be coordinated in order to provide a high degree of service continuity. The critical point is the service bus and the equipment immediately adjacent. The utility system and the building wiring are discussed and recommendations on how to achieve overall design coordination are made... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Resistance of Low-Voltage AC Arcs

    Publication Year: 1970, Page(s):607 - 616
    Cited by:  Papers (51)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (5187 KB)

    Arcing tests conducted in the electrical laboratory indicate that the most probable value of resistance of the low-voltage arc in ohms is equal to 40 divided by the arcing current to the 0.85 power. It is believed that this equation is approximately correct for 120 to 600 volt, 60-Hz ac stable arcing as ir a typical arcing burn-down in a panelboard or switchboard in which the arc length is approxi... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Mining-Shovel Control System

    Publication Year: 1970, Page(s):617 - 629
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (3229 KB)

    The modem control using solid-state circuit elements as used on electric mining shovels in the 4-to 20-cubic yard capacity range is described. The basic feedback principle is discussed and how this is used to obtain the desired characteristics required of a modem shovel control system is demonstrated. Maintenance and trouble shooting of the control system are discussed stressing that a logical app... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Characteristics of Plasma Flame in Metal-Cutting Apparatus of the Transferred-Type Plasma-Jet System

    Publication Year: 1970, Page(s):630 - 637
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (3474 KB)

    Studies were made of the characteristics of the plasma flame in trial-manufactured 60-to l00-kW metal-cutting apparatus of the transferred-type nitrogen plasma-jet system. First, the enthalpy of the plasma flame was measured, and the mean temperature was sought. Next, the line spectra radiated from singly ionized ions of nitrogen were utilized to measure the temperatures of the plasma flame. The m... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Computer-Controlled Transducer Systems: the "Unspecia1ized" Approach to Component Testing

    Publication Year: 1970, Page(s):638 - 646
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (5471 KB)

    Several computer-controlled test stands had been designed and built to monitor and contral life and performance tests on most of the control components which are used in major laundry appliances today. In the process, some of the problems associated with using a real-time process control computer for approval testing were solved while still taking full advantage of the computer's inherent capabili... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Achievements and Prospects in the Utilization of Kinetic Energy

    Publication Year: 1970, Page(s):647 - 652
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (4206 KB)

    Some aspects of the use of kinetic energy at the present state of technology and some new solutions are described. The fundamental element is shown in an operational diagram of an asynchronous motor (induction motor) with a static-frequency converter. A machine designed for manual electric welding, which admits electric arc powers sensibly higher than the power of the supply source, is presented a... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Noncontacting Surface Thermometer for Rollers with Ambient-Temperature Compensation

    Publication Year: 1970, Page(s):653 - 660
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2265 KB)

    The noncontacting thermometer for surface temperature measurement of rollers utilizing the radio frequency eddy current effect is described. A type of bridge is employed in this thermometer. The bridge detects a change in the resistivity of a roller material through the radio-frequency measuring coil. This thermometer has considerably improved accuracy with no time lag. The ambient-temperature inf... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Thermal Protection of Laundry-Appliance Motors

    Publication Year: 1970, Page(s):661 - 668
    Cited by:  Patents (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (7060 KB)

    Laundry-appliance motors have displayed considerable evolution through the 1960's, and this has led to more critical demands on the thermal protector. This evolution is forecast to continue with still increased efficiencies in the utilization of active materials and the development of advanced insulating materials. These demands were understood by engineers experience in designing thermal-protecti... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • An All-Solid-State Digital Control System for Appliances

    Publication Year: 1970, Page(s):669 - 680
    Cited by:  Papers (4)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (8168 KB)

    A completely solid-state control system for domestic appliances has recently been developed at the D&M Research Laboratories. While this system was developed specifically for dish-washers, it is readily applicable to all appliances that exhibit complex control problems. The heart of the system is a large-scale custom metal-oxide semiconductor integrated circuit measuring approximately 0.1 inch on ... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Microwave-Oven Design for Radiation Safety

    Publication Year: 1970, Page(s):681 - 688
    Cited by:  Papers (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (4864 KB)

    A brief review of present knowledge on the biological hazards associated with extremely high-intensity microwave radiation is presented. Existing and proposed safety standards are discussed, including the proposed standard of the U. S. Department of Health, Education, and Welfare and the Bureau of Radiological Health. Instrumentation and measurement techniques are presented. Various door closure s... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Correction to "Two-Speed Single-Winding Single-Phase Induction Motors Using Total Pole-Amplitude Modulation Techniques"

    Publication Year: 1970, Page(s): 689
    Request permission for commercial reuse | PDF file iconPDF (974 KB)
    Full text access may be available. Click article title to sign in or learn about subscription options.
  • IGA Group Chapter Chairmen

    Publication Year: 1970, Page(s): 689-a
    Request permission for commercial reuse | PDF file iconPDF (129 KB)
    Freely Available from IEEE
  • 1970 Index IEEE Transactions on Industry and General Applications Vol. IGA-6

    Publication Year: 1970, Page(s):1 - 6
    Request permission for commercial reuse | PDF file iconPDF (1513 KB)
    Freely Available from IEEE
  • 1970 IEEE Industry and General Applications Group Organization and Membership Directory

    Publication Year: 1970, Page(s):6-a - xxv
    Request permission for commercial reuse | PDF file iconPDF (3346 KB)
    Freely Available from IEEE
  • 1970 Technical Operations Department Organization and Committee Directory of the IEEE Industry and General Applications Group

    Publication Year: 1970, Page(s):xxv-a - axxxi
    Request permission for commercial reuse | PDF file iconPDF (3917 KB)
    Freely Available from IEEE

Aims & Scope

This Transaction ceased production in 1971. The current retitled publication is IEEE Transactions on Industry Applications.

Full Aims & Scope