  • Breakdown Mechanisms in Sulphur-Hexafluoride

    Publication Year: 1978 , Page(s): 135 - 145
    Cited by:  Papers (22)
    Save to Project icon | Request Permissions | PDF file iconPDF (1731 KB)  
    Freely Available from IEEE
  • High Speed Photography of Surface Flashover in Vacuum

    Publication Year: 1978 , Page(s): 145 - 148
    Cited by:  Papers (25)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (1562 KB)  

    The method and results of high speed streak photography of surface flashover in vacuum are presented. It is shown that the bright phase of the flashover arc bridges a 12.5 mm gap in 0.15 ns. The streak records indicate that the flashover arc is preceded by an intense electron burst from the cathode-insulator junction. View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Formation Mechanisms of Clean Zones During the Surface Flashover of Contaminated Insulators

    Publication Year: 1978 , Page(s): 149 - 156
    Cited by:  Papers (12)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (3416 KB)  

    The mechanism of breakdown on a contaminated insulator surface under High Voltage dc (HVDC) has been studied. A new laboratory contamination technique is proposed, which yields uniformly contaminated test specimens. Using this method, flashover processes have been systematically studied and recorded on high speed films. These tests reveal the existence of a "clean zone" around the anode for test v... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • ESR Study of Free Radicals in Electrical Trees in Polyethylene

    Publication Year: 1978 , Page(s): 157 - 163
    Cited by:  Papers (11)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (1231 KB)  

    The electron spin resonance (ESR) spectrum of polyethylene samples containing electrical trees (or, where appropriate, breakdown channels) is found to be rich in structure. Much of this structure is correlated with the conditions under which the tree was produced, thus providing valuable information on the treeing phenomenon. However, in no case thus far has the paramagnetic center responsible for... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Radiation Resistance of Cable Insulating Materials for Nuclear Power Generating Stations

    Publication Year: 1978 , Page(s): 164 - 171
    Cited by:  Papers (9)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (1517 KB)  

    The radiation resistance of sixteen types of representative rubber and plastic materials for cable insulation was studied. The endurance of some crosslinked polymers under the combined environment of thermal aging-radiation-steam (high temperature) was also examined in relation to the chlorine contents of the base polymer and additives (antioxidant, vulcanizers, etc.). Crosslinked polyethylene ins... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • The Morphology of Cross-Linked Polyethylene Insulation

    Publication Year: 1978 , Page(s): 172 - 178
    Cited by:  Papers (23)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (4608 KB)  

    Cross-linked polyethylene, now commonly used for insulation of underground electric distribution cables, is susceptible to electrochemical treeing, in common with other polymeric dielectrics. This treeing phenomenon sometimes originates at holes or cavities present in the cable. A polishing and etching technique has been developed which, when combined with scanning electron microscopy, permits the... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Paper - Oil Insulation - New Definition of Damage

    Publication Year: 1978 , Page(s): 179 - 183
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (496 KB)  

    Results obtained in paper insulation tests have led to a new definition of the damage as D = K (Vn t)á, when the appearance of partial discharges with 25 pC of apparent charge is used aa a failure criteration. It is suggested that the proposed expression for damage can be generalized to the aging of soild insulators if the criterion of total failur of specimens is adopted. View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A Basis Study on Outdoor Insulators of Organic Materials

    Publication Year: 1978 , Page(s): 184 - 193
    Cited by:  Papers (14)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (1492 KB)  

    This paper describes the results of a basic study on the tracking resistance, weathering properties and water absorption of high voltage polymer insulators which are the most important factors for outdoor use. The artificial tracking test proposed in this paper requires a shorter time than the conventional test methods and is capable of ranking materials even when such ranking cannot be made by th... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • The Moisture Absoeption of XLPE Cable Insulation under Simulated Service Conditions

    Publication Year: 1978 , Page(s): 194 - 197
    Cited by:  Papers (18)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (519 KB)  

    First Page of the Article
    View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Method for Visualization of Water Trees by Staining

    Publication Year: 1978 , Page(s): 198 - 199
    Cited by:  Papers (13)
    Save to Project icon | Request Permissions | Click to expandAbstract | PDF file iconPDF (189 KB)  

    First Page of the Article
    View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Errata

    Publication Year: 1978 , Page(s): 200
    Save to Project icon | Request Permissions | PDF file iconPDF (50 KB)  
    Full text access may be available. Click article title to sign in or learn about subscription options.
  • An invitation to Membership

    Publication Year: 1978
    Save to Project icon | Request Permissions | PDF file iconPDF (115 KB)  
    Freely Available from IEEE
  • IEEE Conference Publications Catalog

    Publication Year: 1978 , Page(s): 200-b
    Save to Project icon | Request Permissions | PDF file iconPDF (1034 KB)  
    Freely Available from IEEE
  • Editorial policies and criteria

    Publication Year: 1978 , Page(s): 200-c
    Save to Project icon | Request Permissions | PDF file iconPDF (188 KB)  
    Freely Available from IEEE
  • Information for authors

    Publication Year: 1978 , Page(s): 200d
    Save to Project icon | Request Permissions | PDF file iconPDF (996 KB)  
    Freely Available from IEEE

Aims & Scope

This Transactions ceased production in 1993. The current retitled publication is  IEEE Transactions on Dielectrics and Electrical Insulation.

Full Aims & Scope