By Topic

IEEE Transactions on Power Apparatus and Systems

Issue 1 • Date Jan. 1967

Filter Results

Displaying Results 1 - 17 of 17
  • IEEE Transactions on Power Apparatus and Systems - Table of contents

    Publication Year: 1967, Page(s): c1
    Request permission for commercial reuse | PDF file iconPDF (698 KB)
    Freely Available from IEEE
  • IEEE Power Group

    Publication Year: 1967, Page(s): c2
    Request permission for commercial reuse | PDF file iconPDF (154 KB)
    Freely Available from IEEE
  • News

    Publication Year: 1967, Page(s):1a - 11a
    Request permission for commercial reuse | PDF file iconPDF (3909 KB)
    Freely Available from IEEE
  • Calendar

    Publication Year: 1967, Page(s): 12a
    Request permission for commercial reuse | PDF file iconPDF (142 KB)
    Freely Available from IEEE
  • Cross-Linked Polyethylene for Higher Voltages

    Publication Year: 1967, Page(s):1 - 10
    Cited by:  Papers (17)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (8028 KB)

    The rapid evolution of cross-linked polyethylene for high-voltage cable applications and the factors which promoted this development are discussed in relation to the growing demand for solid-dielectric constructions. Advances in cable design and technology are outlined for this thermally-stable insulation, highlighting the technical advantages of tandem-extruded cross-linked semiconductive shieldi... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Discharge Detection in Extruded Polyethylene Insulated Power Cables

    Publication Year: 1967, Page(s):10 - 34
    Cited by:  Papers (26)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (8140 KB)

    An analytical study was made of the separator-filter type of discharge detector circuit when connected to long cable lengths during corona measurements of polyethylene insulated power cables. Based on this study, it is indicated how optimum detector and connecting circuit parameters can be chosen to best advantage when this type of detection equipment is used in factories where the electrical nois... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Drying and Impregnation of Paper-Insulated Power Cables

    Publication Year: 1967, Page(s):34 - 52
    Cited by:  Papers (8)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (4099 KB)

    The paper describes in some detail the field of drying and impregnation of paper insulated cables. The first part deals with water content of paper, discussing the modes in which this water is held in cellulose and the water content of oil, together with the way in which this water is present in oil. View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • 60-Cycle AC Breakdown of 345-kV Paper Insulated Cable

    Publication Year: 1967, Page(s):53 - 60
    Cited by:  Papers (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (3086 KB)

    High-voltage-time tests at 60 cycles were made with an 800-kV series resonant test set on 21 samples of 345-kV impregnated -paper-insulated high-pressure oil-pipe-type cable. The breakdown level of cables, expressed in equivalent volts per mil for one hour life (V/mil/h) under 200-psig oil pressure decreased from 1130 to 850 V/mil/h when the conductor temperature was increased from 70 to 110°C. A... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • EHV Cables with Compressed SF6 Gas Insulation

    Publication Year: 1967, Page(s):60 - 66
    Cited by:  Papers (14)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (3882 KB)

    An EHV power cable with compressed pure SF6 gas insulation was produced experimentally, and succeeded in the dielectric withstand test. The outside diameter of one phase of the cable was 14 inches. The conductor, composed of a metal pipe 4¿inches in diameter, was arranged at the center of the outer pipe, and supported by spacers placed at intervals of about 15 feet. View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • A Study of Application of Cable Lapping Theory to EHV Cables

    Publication Year: 1967, Page(s):66 - 81
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (3149 KB)

    Two categories of lapping theory for paper-insulated cable are reviewed. The first category, old and established, analyzes the structure of the paper lapping which influences the electric strength of the cable in terms of the paper registration only, e.g. 65/35 registration. The second category, recently developed and based on the mathematical theory of elasticity involving both the paper dimensio... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • EHY Cables: Present Situation in France

    Publication Year: 1967, Page(s):81 - 92
    Cited by:  Patents (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (5082 KB)

    The authors first give a short description of the existing 225-kV underground system of the Paris area, where oil-pressure pipe-type cables have been mainly used since 1954. The new plans of development of this system call for new 225-kV cables, which will supply 225/20-kV distribution substations right in the heart of the city. Self-contained single-conductor cables would probably present some ad... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Progress with Underground Transmission Cable Engineering in Great Britain

    Publication Year: 1967, Page(s):93 - 105
    Cited by:  Papers (3)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2736 KB)

    This paper surveys British progress, over a five-year period since an earlier paper [1], in meeting the steeply rising demand for electricity. During this period EHV cables, having over twice the conductor section and power transfer capabilities previously used, have been designed and manufactured. View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Inside Hydrothermal Coordination

    Publication Year: 1967, Page(s):106 - 117
    Cited by:  Papers (7)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (2646 KB)

    The various factors involved in hydrothermal coordination and their interrelation required for optimum operation are discussed. Also, the relative advantages and disadvantages of various methods available for obtaining optimum operation of hydrothermal systems are compared. In addition, a basis for an on-line control computer is suggested and its possible advantages are discussed briefly. View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Field Tests and Design Evaluation of a 230-kV 20 000-MVA Oil Circuit Breaker

    Publication Year: 1967, Page(s):117 - 129
    Cited by:  Papers (1)
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (6459 KB)

    Recent field tests of a 230-kV, 20 000-MVA oil circuit breaker are discussed and evaluated. Initial test results revealed requirements for design modifications, the nature of which are reviewed. An interim field development test and the final acceptance tests are renewed and data are presented. The need for a developmental field test site and the characteristics and organization of one such facili... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Pulse Testing Laboratory for Interrupting Device Development

    Publication Year: 1967, Page(s):129 - 136
    Request permission for commercial reuse | Click to expandAbstract | PDF file iconPDF (7798 KB)

    The development of circuit interrupting devices can be accomplished more efficiently if not delayed by problems which are related to the laboratory in which tests are made. A unique current pulse laboratory has been created which simplifies the connection of test samples to the source of power. The control and timing of switching devices has been automated to reduce the time required for adjustmen... View full abstract»

    Full text access may be available. Click article title to sign in or learn about subscription options.
  • Contributors

    Publication Year: 1967, Page(s):137 - 139
    Request permission for commercial reuse | PDF file iconPDF (4423 KB)
    Freely Available from IEEE
  • Blank Page

    Publication Year: 1967, Page(s): 139a
    Request permission for commercial reuse | PDF file iconPDF (14 KB)
    Freely Available from IEEE

Aims & Scope

This Transactions ceased production in 1985. The current retitled publication is IEEE Transactions on Energy Conversion and IEEE Transactions on Power Delivery, and IEEE Transactions on Power Systems.

Full Aims & Scope