Cart (Loading....) | Create Account
Close category search window
 

Natural contamination test of insulators with DC voltage energization at inland areas

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Takasu, K. ; Central Res. Inst., Electr. Power Ind., Tokyo, Japan ; Shindo, T. ; Arai, Noboru

Results of tests for natural contamination of insulator strings in inland areas are discussed. Natural exposure tests with -280 kV DC voltage energization were carried out for 5 years. The following results were obtained: (1) The amount of contaminant on the bottom surface increased with the length of the exposure period, for the first year, at inland areas. Therefore, estimates of contamination severity should use data obtained for exposure periods of at least one year. (2) Insulators near the line and ground sides of a string collect more contaminant than the middle when DC voltage is applied. However, the effect of nonuniform contamination on DC withstand voltage is not as great as expected when ratios of the number of heavily contaminated insulators to that of insulator string are from 15% to 30%. (3) No significant effect of DC voltage energization on the ESDD of the middle part of insulator strings has been observed when the applied voltage is no higher than 280 kV DC. (4) A pollution severity map established for AC transmission lines can be used for the determination of design ESDD for HVDC transmission lines for inland areas without industrial contamination. (5) The maximum value of leakage current under natural conditions is less than 3 mA, and no flashover has been experienced during these 5 years for electrical stress from 90 to 120 kV/m. The application of these results to insulation design for HVDC transmission lines is discussed

Published in:

Power Delivery, IEEE Transactions on  (Volume:3 ,  Issue: 4 )

Date of Publication:

Oct 1988

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.