Optimal Regular-Sampled PWM Inverter Control Techniques
Bowes, S.R.
Holliday, D.
Dept. of Electr. & Electron. Eng., Bristol Univ.;
This paper appears in: Industrial Electronics, IEEE Transactions on
Publication Date: June 2007
Volume: 54,
Issue: 3
On page(s): 1547-1559
ISSN: 0278-0046
INSPEC Accession Number: 9477527
Digital Object Identifier: 10.1109/TIE.2007.894767
Current Version Published: 2007-04-23
Abstract
A survey of eight different advanced Regular-Sampled pulsewidth-modulation (PWM) strategies is presented and compared for three-phase inverters. The PWM strategies represent modifications of the basic Regular-Sampled technique and are designed to closely reproduce the "exact" switching angles and performance of the well-known Harmonic Elimination, Harmonic Minimization, Space Vector Modulation, High-Frequency, and Hysteresis Band PWM strategies. Each strategy is compared, and the advantages and disadvantages of each are emphasized in terms of complexity and implementation. Experimental and computer-aided design simulation results are presented to show the differences between the various strategies and to confirm the validity and accuracy of each of the techniques
Index
Terms
Available to subscribers and IEEE members.
References
Available to subscribers and IEEE members.
Citing Documents