Abstract:
The possibilities for improving the efficiency of an indirect-fired strip annealing furnace with radiant tubes are explored. First, the influence of the fuel/air-ratio on...Show MoreMetadata
Abstract:
The possibilities for improving the efficiency of an indirect-fired strip annealing furnace with radiant tubes are explored. First, the influence of the fuel/air-ratio on the efficiency is analyzed by means of linearized relationships. Second, the optimum operating range of an individual radiant tube and a new control strategy for the fuel supply are derived. Both analyses are based on the balance model of a single radiant tube. The input data were taken from an experimental measurement campaign of an industrial furnace.
Published in: 2013 European Control Conference (ECC)
Date of Conference: 17-19 July 2013
Date Added to IEEE Xplore: 02 December 2013
Electronic ISBN:978-3-033-03962-9