Scheduled System Maintenance:
Some services will be unavailable Sunday, March 29th through Monday, March 30th. We apologize for the inconvenience.
By Topic

Influence of metal inclusions on AC breakdown strength in EPDM

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

The purchase and pricing options are temporarily unavailable. Please try again later.
2 Author(s)
Svahn, J. ; ABB Kabeldon, Alingsas, Sweden ; Gubanski, S.M.

The aim of this work was to investigate the influence of metallic particles on the AC breakdown strength in EPDM rubber. Filled and unfilled EPDM rubbers were contaminated with two different particle sizes (50 μm and 165 μm) and different particle concentrations, to ascertain their influence on the breakdown strength. The inclusions were irregularly shaped iron particles. The breakdown tests were carried out by using ~0.7 mm thick circular rubber slabs between cylindrical electrodes. The result yielded the characteristic AC breakdown strengths of 78 kV/mm and 86 kV/mm respectively for non-contaminated filled and unfilled rubbers. The electric strength was considerably lowered for larger inclusions but not in the case of smaller ones. A statistical evaluation of the results is also provided

Published in:

Conduction and Breakdown in Solid Dielectrics, 1998. ICSD '98. Proceedings of the 1998 IEEE 6th International Conference on

Date of Conference:

22-25 Jun 1998