Cart (Loading....) | Create Account
Close category search window
 

Soft Fiber Optic Sensors for Precision Measurement of Shear Stress and Pressure

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Zhang, Z.F. ; Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Kowloon, Hong Kong ; Tao, X.M. ; Zhang, H.P. ; Zhu, B.

This paper reports a soft fiber optic sensor based on polymer fiber Bragg gratings (PFBGs) for simultaneous measurement of shear and normal stresses. The sensor comprises two PFBGs embedded in soft polydimethylsiloxanes (PDMS) matrix, and one of them is horizontally placed while the other is tilted. The transduction principle is that applied normal and/or shear stresses lead to deformation of the matrix and induce strains on gratings. Finite element simulation reveals non-uniform strain distribution along two fibers for direct imbedding that is verified by theoretical analysis, and therefore four gaskets are used to stretch polymer optical fibers from two ends and to produce strains on gratings. The fabricated sensor is tested by concurrently applying normal and shear forces, and Bragg wavelength shifts of two gratings were found to be linearly dependent on stresses in two directions. The measured pressure sensitivity is 0.8 pm/Pa in the range of 2.4 kPa and the shear stress sensitivity is 1.3 pm/Pa for a full range of 0.6 kPa. Such soft sensors are especially suitable for high precision measurement of contact stresses involving human skins and tissues because they are similar in Young's modulus to the used PDMS.

Published in:

Sensors Journal, IEEE  (Volume:13 ,  Issue: 5 )

Date of Publication:

May 2013

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.