By Topic

A new method to reduce frequency-temperature coefficient of sapphire-loaded cavities for compact hydrogen masers

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Ren-fu Yang ; Beijing Inst. of Radio Metrol. & Meas., Beijing, China ; Tie-zhong Zhou ; Hai-bo Chen ; Nuan-rang Wang
more authors

To reduce the size and weight of the hydrogen maser atomic clocks, some useful attempts and related research results about sapphire-loaded cylindrical cavities for hydrogen masers were reported by the Beijing Institute of Radio Metrology and Measurement. The fractional frequency stability of the order of 10??15 over 10 000 seconds can be realized. However, because of a large frequency-temperature coefficient in a single sapphire bulb in the cavity, further improvement of the stability in the compact hydrogen clock was restricted. In this work, we chose several small single-crystal chips of SrTiO3 with a large negative frequency-temperature coefficient to compensate the sapphire microwave cavity. Based on the theoretical calculation, the frequency-temperature coefficient in the TE011 mode of a sapphire cavity associated with several small chips of SrTiO3 can be greatly reduced. A sapphire-loaded cavity and 8 compensated chips of SrTiO3 were prepared, and a combined cavity was simulated by finite element method and measured by experiments. When quality factor was kept above 40 000, the frequency-temperature coefficient can be reduced to about 1/5 of its starting value. The experimental results agree very well with the calculation and simulation. Furthermore, this new method was applied in the compact hydrogen maser. Because of the decrease of temperature frequency shift, the hydrogen maser stability at medium- and long- term averaging time from 1 s to 105 s has an obvious improvement compared with the our previous results.

Published in:

Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on  (Volume:57 ,  Issue: 3 )