In this paper a simple dynamic model for a PMSM with inter-turn winding fault is derived. FEM is used for parameter determination of the machine with inter-turn fault. This fault model is used to study the behavior of the machine with inter-turn fault. The experimental test is conducted to validate the fault model for different levels of fault severity. The comparison of the results obtained by the model simulation and experimental tests allowed verifying the precision of the proposed dynamic model. This fault model is used to study of the PMSM under various fault conditions and severity and seems to be well adapted for PM motors health monitoring and inter-turn fault diagnosis.

Published in:

Industry Applications Society Annual Meeting, 2008. IAS '08. IEEE

Date of Conference:

5-9 Oct. 2008

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.