By Topic

A few formulation of the magnetic vector potential method in 3-D multiply connected regions

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

1 Author(s)
Morisue, T. ; Tokushima Univ., Japan

Formulations using the continuous and discontinuous magnetic vector potential for 3-D eddy current calculation in both the simply and multiply connected regions are presented. The formulation using the continuous magnetic vector potential does not need cutting for the multiply-connected-region problem, but it needs the electric scalar potential. The formulation using the discontinuous magnetic vector potential does not need the electric scalar potential for the simply-connected-region problem, but it needs cutting for the multiply-connected region problem, so additional computation is required. Thus the former may suite the multiply-connected-region problem, while the latter may suit the simply-connected region problem

Published in:

Magnetics, IEEE Transactions on  (Volume:24 ,  Issue: 1 )