Courtecuisse, V. ; National Center of Technological Research (CNRT FUTURELEC), Laboratoire d''Electrotechnique et d''Electronique de Puissance de Lille (L2EP), Ecole des Hautes Etudes d''Ingénieur (HEI), 13 rue de Toul, F-59046 Lille Cedex, France ; Robyns, B. ; Francois, B. ; Plumel, S.
more authors

To maintain a power reserve to contribute to the primary frequency control with a variable speed wind generator, a fuzzy logic based multivariable control strategy is proposed in this paper. The main result of this paper is to shown that it is possible to create a regular reserve whatever the wind speed without any wind speed measurement. The performance of the proposed primary frequency control strategies are shown with the help of simulations by considering a wind farm including three wind generators.

Published in:

Power Engineering, Energy and Electrical Drives, 2007. POWERENG 2007. International Conference on

Date of Conference:

12-14 April 2007