By Topic

Lessons learned in building a fault-tolerant CORBA system

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Narasimhan, P. ; Inst. of Software Res. Int., Carnegie Mellon Univ., Pittsburgh, PA, USA ; Moser, L.E. ; Melliar-Smith, P.M.

The Eternal system pioneered the interception approach to providing transparent fault tolerance for CORBA, which allows it to make a CORBA application reliable with little or no modification to the application or the ORB. The design and implementation of the Eternal system has influenced industrial practices by providing the basis for the specifications of the fault-tolerant CORBA standard that the Object Management Group adopted. We discuss our experience in developing the Eternal system, with particular emphasis on the challenges that we encountered and the lessons that we learned.

Published in:

Dependable Systems and Networks, 2002. DSN 2002. Proceedings. International Conference on

Date of Conference: