Slotted surface treatment of position-sensitive NaI(Tl) detectors to improve detector performance

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Surti, S. ; Dept. of Radiol., Pennsylvania Univ., Philadelphia, PA, USA ; Freifelder, R. ; Karp, J.S.

We have investigated cutting slots in the entrance surface of 1-in-thick NaI(Tl) crystals, which are used in large position-sensitive detectors, to narrow the detector light response function (LRF). The LRF describes the spread of light from the crystal to the photomultiplier tube (PMT) array. A narrow LRF will, therefore, reduce pileup effects in these detectors at high count rates, and so improve the count-rate performance of NaI(Tl)-based positron emission tomography (PET) scanners. The slot pitch was kept fixed at 5 mm to take into consideration the time required to cut the slots and the slight reduction in sensitivity for the slotted detector. Slots will narrow the LRF and simultaneously make the detector response to position changes discrete in nature. Our investigation focuses on optimizing the slot depth and PMT readout array to achieve a narrow LRF with a detector spatial resolution close to that of the 5-mm slot pitch. Our measurements and simulations show the narrowing of the LRF for large two-dimensional (2-D) detectors with increasing slot depth. However, using 50-mm PMTs the variation of the point spread function between adjacent slots, together with the discrete 5-mm sampling, results in a worsening of the detector spatial resolution for a slotted detector compared to a similar unslotted detector. Simulations show that using smaller 39-mm PMTs will result in better position sampling and a reduction in the variation of the point spread function (PSF) in between adjacent slots. The 2-D detector with 15-mm-deep slots and 39-mm. PMTs results in a detector spatial resolution which is similar to that of an unslotted detector. However, the LRF of this slotted detector is significantly narrower (about 35%), thus reduced event pileup would be expected at high count rates

Published in:

Nuclear Science, IEEE Transactions on  (Volume:48 ,  Issue: 6 )

Date of Publication:

Dec 2001

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.