Cart (Loading....) | Create Account
Close category search window
 

Volume delineation by fusion of fuzzy sets obtained from multiplanar tomographic images

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Vial, S. ; Lab. de Biophys., Univ. des Sci. et Technol., Lille, France ; Gibon, D. ; Vasseur, C. ; Rousseau, Jean

Techniques of three-dimensional (3-D) volume delineation from tomographic medical imaging are usually based on 2-D contour definition. For a given structure, several different contours can be obtained depending on the segmentation method used or the user's choice. The goal of this work is to develop a new method that reduces the inaccuracies generally observed. A minimum volume that is certain to be included in the volume concerned (membership degree μ=1), and a maximum volume outside which no part of the volume is expected to be found (membership degree μ=0), are defined semi-automatically. The intermediate fuzziness region (0<μ<1) is processed using the theory of possibility. The resulting fuzzy volume is obtained after data fusion from multiplanar slices. The influence of the contrast-to-noise ratio was tested on simulated images. The influence of slice thickness as well as the accuracy of the method were studied on phantoms. The absolute volume error was less than 2% for phantom volumes of 2-8 cm 3, whereas the values obtained with conventional methods were much larger than the actual volumes. Clinical experiments were conducted, and the fuzzy logic method gave a volume lower than that obtained with the conventional method. Our fuzzy logic method allows volumes to be determined with better accuracy and reproducibility.

Published in:

Medical Imaging, IEEE Transactions on  (Volume:20 ,  Issue: 12 )

Date of Publication:

Dec. 2001

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.