With the analysis of heat and temperature-transfer in generator stator windings, the temperature hydraulic model of large steam generator stator windings is found. That is the calculation method for copper temperature and the temperature of water outlet (standard temperature) in steam generator stator windings on the normal running condition (no-fault and well-running condition), which is verified by many kinds of working condition data