Discussion of "Partitioning of synchronous machine windings for internal fault analysis" [Comments and authors' reply]

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

7 Author(s)

M.T. Holmberg et al. comment on the original paper by P.P. Reichmeider et al. (see ibid., vol.15, no.4, p.372-9, 2000). They point out that the authors do not appear to have mentioned as to how leakage inductance for part of the winding would be determined once the winding is partitioned. The original authors reply to the comments.

Published in:

Energy Conversion, IEEE Transactions on  (Volume:16 ,  Issue: 4 )