In this paper, a unified constant-frequency integration control (UCI) scheme is proposed for a three-phase active power filter (APF). The proposed control method eliminates the need of sensing the three-phase load current, the nontrivial task of calculating the harmonics and reactive current components, as well as the use of any multipliers, as required by previously reported control methods. By applying one-cycle control and sensing the mains line current, unity power factor and low input current distortion can be realized by one integrator with reset along with a few linear and logic components such as flip-flops, comparators, and clock. All findings are supported by experimental results
Published in:
Power Electronics Specialists Conference, 2001. PESC. 2001 IEEE 32nd Annual
(Volume:3
)