Retinal thickness measurements from optical coherence tomography using a Markov boundary model

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Koozekanani, D. ; Dept. of Electr. Eng., Ohio State Univ., Columbus, OH, USA ; Boyer, K. ; Roberts, C.

Presents a system for detecting retinal boundaries in optical coherence tomography (OCT) B-scans. OCT is a relatively new imaging modality giving cross-sectional images that are qualitatively similar to ultrasound. However, the axial resolution with OCT is much higher, on the order of 10 μm. Objective, quantitative measures of retinal thickness may be made from OCT images. Knowledge of retinal thickness is important in the evaluation and treatment of many ocular diseases. The boundary-detection system presented here uses a one-dimensional edge-detection kernel to yield edge primitives. These edge primitives are rated, selected, and organized to form a coherent boundary structure by use of a Markov model of retinal boundaries as detected by OCT. Qualitatively, the boundaries detected by the automated system generally agreed extremely well with the true retinal structure for the vast majority of OCT images. Only one of the 1450 evaluation images caused the algorithm to fail. A quantitative evaluation of the retinal boundaries was performed as well, using the clinical application of automatic retinal thickness determination. Retinal thickness measurements derived from the algorithm's results were compared with thickness measurements from manually corrected boundaries for 1450 test images. The algorithm's thickness measurements over a 1-mm region near the fovea differed from the corrected thickness measurements by less than 10 μm for 74% of the images and by less than 25 μm (10% of normal retinal thickness) for 98.4% of the images. These errors are near the machine's resolution limit and still well below clinical significance. Current, standard clinical practice involves a qualitative, visual assessment of retinal thickness. A robust, quantitatively accurate system such as the authors' can be expected to improve patient care.

Published in:

Medical Imaging, IEEE Transactions on  (Volume:20 ,  Issue: 9 )