Scheduled System Maintenance on May 29th, 2015:
IEEE Xplore will be upgraded between 11:00 AM and 10:00 PM EDT. During this time there may be intermittent impact on performance. We apologize for any inconvenience.
By Topic

Localization of the site of origin of cardiac activation by means of a heart-model-based electrocardiographic imaging approach

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Guanglin Li ; Dept. of Electr. Eng. & Comput. Sci., Illinois Univ., Chicago, IL, USA ; He, B.

The authors have developed a new approach to solve the inverse problem of electrocardiography in terms of heart model parameters. The inverse solution of the electrocardiogram (ECG) inverse problem is defined, in the present study, as the parameters of the heart model, which are closely related to the physiological and pathophysiological status of the heart, and is estimated by using an optimization system of heart model parameters, instead of solving the matrix equation relating the body surface ECGs and equivalent cardiac sources. An artificial neural network based preliminary diagnosis system has been developed to limit the searching space of the optimization algorithm and to initialize the model parameters in the computer heart model. The optimal heart model parameters were obtained by minimizing the objective functions, as functions of the observed and model-generated body surface ECGs. The authors have tested the feasibility of the newly developed technique in localizing the site of origin of cardiac activation using a pace mapping protocol. The present computer simulation results show that, the present approach for localization of the site of origin of ventricular activation achieved an averaged localization error of about 3 mm [for 5-μV Gaussian white noise (GWN)] and 4 mm (for 10-μV GWN), with standard deviation of the localization errors of being about 1.5 mm. The present simulation study suggests that this newly developed approach provides a robust inverse solution, circumventing the difficulties of the ECG inverse problem, and may become an important alternative to other ECG inverse solutions.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:48 ,  Issue: 6 )