4 Author(s)
Benedikt, J. ; Sch. of Eng., Cardiff Univ., UK ; Gaddi, R. ; Tasker, P.J. ; Goss, M.

A measurement system combining vector corrected waveform measurements with active harmonic load-pull extends, for the first time, real-time experimental waveform engineering up to the 30-W power level. The vector correction procedure is presented in this paper. A novel harmonic load-pull approach based on the real-time measurement capability of the system is demonstrated on a 4-W LDMOS device. A 20% increase in maximum output power to 4.7 W without degrading gain and efficiency is realized. Waveform analysis at various drive and load conditions directly identifies nonlinear capacitance effects being a key design issue for the design of highly efficient power amplifier

Published in:

Microwave Theory and Techniques, IEEE Transactions on  (Volume:48 ,  Issue: 12 )