Estimation of current leakage in left and right ventricular conductance volumetry using a dynamic finite element model

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Gopakumaran, B. ; Dept. of Cardiothoracic Anesthesia, Cleveland Clinic Found., OH, USA ; Petre, J.H. ; Sturm, B. ; White, R.D.
more authors

Leakage of electric current through cardiac structures surrounding the ventricle is a primary source of error during ventricular volume measurements using a conductance catheter. This error can be represented as a leakage volume, V L. V L is generally estimated by a saline-bolus method, and is assumed constant throughout the cardiac cycle. However, dynamic changes in ventricular volume and cardiac wall thickness could change V L. To estimate V L, a dynamic finite element model of the heart was developed based on MR images. Conductance measurements were simulated using a modeled conductance catheter, and true V L was calculated. V L varied from 22.7 ml (end-systole) to 26.4 ml (end-diastole) in the left ventricle and from 19.9 ml (end-systole) to 26.9 ml (end-diastole) in the right ventricle. The saline-bolus method underestimated V L in both the left (V L=19.4 ml) and the right (V L=4.1 ml) ventricular volume measurements. V L increased linearly with the ratio of blood to tissue resistivity, and changed minimally with catheter position. These results indicate that V L has to be estimated dynamically throughout the cardiac cycle to obtain accurate cardiac volume measurements. The results also show that the saline bolus method does not estimate current leakage accurately, especially in the right ventricular volume measurement.

Published in:
Biomedical Engineering, IEEE Transactions on  (Volume:47 ,  Issue: 11 )

Date of Publication: Nov. 2000