By Topic

The BNM-LPTF software for the frequency comparison of atomic clocks by the carrier phase of the GPS signal

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

6 Author(s)
Taris, F. ; Lab. Primaire du Temps et des Frequences, Bur. Nat. de Metrol., Paris, France ; Uhrich, P. ; Petit, G. ; Zhiheng Jiang
more authors

This paper describes the software and equipment used at the Laboratoire Primaire du Temps et des Frequences du Bureau National de Metrologie (BNM-LPTF), Paris, France. Two H-masers in short baseline, one located at the BNM-LPTF and the other at the Laboratoire de l'Horloge Atomique du Centre National de la Recherche Scientifique (CNRS-LHA), Orsay, France, were computed in parallel with the BNM-LPTF software and with the BERNESE V 4.1 software. The comparison of the results issued from both computations shows an agreement within 100 ps (1 /spl sigma/). In addition, comparisons with the BNM-LPTF software were made over 10 days with the H-masers located at the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany, and another at the National Physical Laboratory (NPL), Teddington, United Kingdom. The data collected show that a modulation with an amplitude of 50 ps and a period of 700-800 ps affects the equipment of the NPL. In addition, these comparisons show that the noise of the instruments together with the environmental conditions at the PTB was higher than that of the NPL and the BNM-LPTF during the observation period. The best relative frequency stability obtained, in the BNM-LPTF/NPL comparison, is about 3/spl times/10/sup -15/ for averaging periods between 6/spl times/10/sup 4/ s and 3/spl times/10/sup 5/ s. This result is in good agreement with the expected stability of H-masers. It demonstrates that the noise brought by the GPS carrier phase measurements can be averaged out at this level.

Published in:

Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on  (Volume:47 ,  Issue: 5 )