Techniques to improve the spatial sampling of MicroPET-a high resolution animal PET tomograph

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Chatziioannou, A. ; Sch. of Med., California Univ., Los Angeles, CA, USA ; Silverman, R.W. ; Meadors, K. ; Farquhar, T.H.
more authors

A method is described to improve the spatial sampling of microPET, a high resolution PET scanner designed for imaging small laboratory animals. The high intrinsic resolution of the microPET detector (1.58 mm FWHM), in combination with the stationary ring geometry of the tomograph, generate an imaging system which is inherently spatially undersampled. As a result the imaging resolution measured with a three-dimensional (3-D) filtered backprojection (FBP) algorithm for a point source at the center of the field of view (CFOV) is only 1.8 mm FWHM and has large fluctuations at positions near the CFOV. A small wobble motion was introduced via a circular motion of the scanner bed in the transverse plane, with a wobble radius of 300 μm. The data was acquired with a step-and-shoot method by dividing the wobble circle into a number of equidistantly sampled intervals. The separate sinograms were interpolated to a finely resampled sinogram, which was reconstructed with the 3-D filtered backprojection algorithm. The resulting images demonstrated full recovery of the intrinsic detector resolution and elimination of the local nonuniformities of the point spread function (PSF) at the CFOV, with three wobble samples. The resulting average resolution improvement fur the central 5 cm of the FOV was approximately 13% in the radial and 19% in the tangential direction, with an associated 50% penalty in the reconstructed image noise

Published in:

Nuclear Science, IEEE Transactions on  (Volume:47 ,  Issue: 2 )