Cart (Loading....) | Create Account
Close category search window
 

The effect of contraction and twist on myocardial PET and SPECT image resolution: a mathematical phantom study

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

1 Author(s)
Smith, M.F. ; Dept. of Nucl. Med., Nat. Inst. of Health, Bethesda, MD, USA

Motion of the heart degrades cardiac PET and SPECT resolution. A mathematical phantom was constructed to model contractile and non-uniform twisting motions of the left ventricular myocardium as the heart beats. The phantom was used to estimate the effect of motion on cardiac ECT image resolution and on quantitation in regions of interest (ROIs). Cardiac motion with contraction and twist was simulated at 16 time gates. The movement of mid-myocardial points was tracked, from which motion blur was computed. Contractile motion was greater near the base and twisting motion was greater near the apex. The blur due to both motions was equivalent to 7-9 mm FWHM Gaussian smoothing. Clinical PET resolution of 7 mm was degraded to 10-11 mm FWHM and clinical SPECT resolution of 14 mm to 16-17 mm FNHM. Weighting coefficients were used to characterize how activity in short and long axis ROIs was related to activity in source model ROIs. The effect of contraction was dependent on whether short or long axis slices were used for ROIs and on the spatial location of the ROIs. The weights for short axis ROIs showed the effect of twist in blurring activity to adjacent angular sectors. This effect was not seen in long axis ROIs where the angular range encompassed by the constant thickness slices was greater. A mathematical heart phantom that models contractile and twisting motions is valuable for investigating the effect of these motions on cardiac ECT studies

Published in:

Nuclear Science Symposium, 1999. Conference Record. 1999 IEEE  (Volume:3 )

Date of Conference:

1999

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.