X- and gamma-ray hardness of floating-gate EEPROM technology as applied to implantable medical devices

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Prutchi, D. ; Impulse Dynamics, Lake Jackson, TX, USA ; Prince, J. ; Stotts, L.J.

There is a growing need for the inclusion of nonvolatile memory within implantable medical devices in order to store product identification, operating parameters, calibration information, as well as patient and diagnostic data. Due to the critical nature of the application however, the data retention reliability is of utmost importance. In the case of nonvolatile memories, a source of concern regards their exposure to ionizing radiation as the result of diagnostic or therapeutic procedures performed on the patient. This paper reports on X- and gamma-ray experiments and calculations on a representative modern electrically erasable and programmable read-only memory (EEPROM) (Atmel 24C64). No transient upsets due to 150 kVp X-rays were observed in 10 unbiased and five biased DTU's up to the maximum achievable 27 rad(Si)/s for a total dose of 200 rad(Si). Unbiased parts had no failure to an average total-dose of 40.9 krad(Si). The lowest failure level observed for an unbiased part was 30.0 krad(Si). In the biased parts, the read-mode operating current increased as a function of total dose from 47 μA prior to exposure to 385 μA at 30 krad(Si). The mean highest no-failure level for 10 unbiased parts exposed to Co60 gamma-rays was 36.9 krad(Si) with a sigma of 2.3. Five biased DUT failures occurred at a mean of 27.84 krad(Si) with a sigma of 2.42. The analysis of these data, in comparison to maximum therapeutic photon radiation doses suggest that floating-gate EEPROM technology is reliable in the presence of photon ionizing-radiation exposures typical of medical diagnostic and therapeutic environments

Published in:

Components and Packaging Technologies, IEEE Transactions on  (Volume:22 ,  Issue: 3 )